Abstract

When radiant systems are installed in highly glazed rooms large amounts of solar radiation directly hit the cooled surface; this specific behavior of radiant systems in this situation should be studied in order to modify the procedure that is traditionally applied to design radiant cooling systems. Furthermore, radiant systems behave in different ways depending on their thermal mass. Based on previous researches, a model is proposed in this work to determine the conversion of heat gains into cooling loads; the model is specifically adapted to highly glazed buildings, and is differentiated for low and high thermal masses radiant systems. A numerical model is developed to provide a calculation example that confirms the proposed procedure.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Gaw W, Holst S, Reuss S, Simmonds P (2000) Using radiant cooled floors to condition large spaces and maintain comfort conditions. ASHRAE Transactions 106(1):695–701

    Google Scholar 

  2. Causone F, Corgnati SP, Filippi M, Olesen BW (2009) Solar radiation and cooling load calculation for radiant systems: definition and evaluation of the Direct Solar Load. Energy Build. doi:10.1016/j.enbuild.2009.09.008

    Google Scholar 

  3. Causone F, Corgnati SP, Filippi M (2007) Calculation method for summer cooling with radiant panels. In: CLIMA 2007 WellBeing Indoors, Helsinki

    Google Scholar 

  4. Corgnati SP, Fracastoro GV, Perino M (2000) Un metodo di calcolo per il dimensionamento dei soffitti radianti per il raffrescamento estivo. CDA 7:731–741

    Google Scholar 

  5. ASHRAE Handbook Fundamentals (2009)—SI Edition

    Google Scholar 

  6. Causone F, Corgnati SP, FIlippi M, Olesen BW (2009) Experimental evaluation of heat transfer coefficients between radiant ceiling and room. Energy Build 41:622–628

    Article  Google Scholar 

  7. Causone F, Baldin F, Olesen BW, Corgnati SP (2010) Floor heating and cooling combined with displacement ventilation: possibilities, limitations. Energy Build 42:2338–2352

    Article  Google Scholar 

  8. Corgnati SP, Fracastoro GV, Perino M (2000) Sistemi radianti per il raffrescamento estivo: dinamiche di asportazione dei carichi termici. In: Congressi ATI-55, Matera

    Google Scholar 

  9. De Carli M, Tonon M (2011) Effect of modeling solar radiation on the cooling performance of radiant floors. Sol Energy 85:689–712

    Article  Google Scholar 

  10. Chatziangelidis K, Bouris D (2008) Calculation of the distribution of incoming solar radiation in enclosures. Appl Therm Eng 29:1096–1105

    Article  Google Scholar 

  11. Bouchair A (2004) Infinite reflections method for calculation of radiation exchange between Grey-Diffuse surfaces : Up to four surface interactions (Part 1). Rev Energ Ren 7:53–71

    Google Scholar 

  12. Koschenz M, Dorer V (1996) Interaction of an air system with concrete core conditioning. Energy Build 30:139–145

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Stefano P. Corgnati .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Corgnati, S.P., Jarre, M. (2014). Radiant Floor Behavior in Removing Cooling Loads from Large Glassed Buildings. In: Li, A., Zhu, Y., Li, Y. (eds) Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning. Lecture Notes in Electrical Engineering, vol 262. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-39581-9_24

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-39581-9_24

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-39580-2

  • Online ISBN: 978-3-642-39581-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics