Skip to main content
  • 39 Accesses

Zusammenfassung

Die Xe-CT-Methode ist eine transmissionstomographische Methode zur Hirndurchblutungsmessung. Bis zu 3 parallel gelegene Schichten können gleichzeitig untersucht werden. Da es sich um eine Röntgen-CT-Methode handelt, entspricht die anatomische Korrelation der Meßwerte grundsätzlich dem Auflösungsvermögen des CT-Gerätes.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Literatur

  1. Aritake K, Segawa H, Yoshimasu N, Nakamura O, Kimura K, Takakura K, Brock M (1985) Cerebral blood flow study in patients with intra-cranial tumors by CT with stable Xenon enhancement. In: Hartmann/Hoyer (eds) Cerebral blood flow and metabolism measurement. Springer, Berlin Heidelberg New York, pp 350–355

    Chapter  Google Scholar 

  2. Blasberg RG, Molnar P, Horowitz M, Kornblith P, Pleasants R, Fenstermacher J (1983) Regional blood flow in RT-9 brain tumors. J Neurosurg 58:863–873

    Article  PubMed  CAS  Google Scholar 

  3. Gur D, Wolfson SK, Yonas H, Good WF, Shabason L, Latchaw RE, Miller DM, Cook EE (1982) Progress in cerebrovascular disease: local cerebral blood flow by Xenon enhanced CT. Stroke 13:750–758

    Article  PubMed  CAS  Google Scholar 

  4. Nakamura O, Nomura K, Segawa H, Takakura K, Nakagome T, Yoshimasu N, Ueda Y, Kimura K, Nagai M (1985) rCBF in brain tumors as measured by Xenon enhanced CT. No Shinkei Geka 13:37–43

    PubMed  CAS  Google Scholar 

  5. Reulen HJ, Hadjidimos A, Schiirmann K (1972) The effect of dexamethasone on water and electrolyte content and on rCBF in perifocal brain edema in man. In: Reulen HJ, Schürmann K (eds) Steroids and brain edema. Springer, Berlin Heidelberg New York, pp 239–252

    Chapter  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1988 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Holl, K., Nemati, M.N., Dietz, H., Majewski, A. (1988). Intrakranielle Tumoren im Xenon-CT-Bild. In: Schneider, G.H., Vogler, E. (eds) Digitale bildgebende Verfahren Interventionelle Verfahren Integrierte digitale Radiologie. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-73134-1_16

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-73134-1_16

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-73136-5

  • Online ISBN: 978-3-642-73134-1

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics