Skip to main content

An Automatic Peak Detection and Evaluation Program for Somatosensory Evoked Potential (SSEP) Monitoring

  • Conference paper
Intraoperative Neurophysiologic Monitoring in Neurosurgery

Summary

An almost fully automatized program for evaluation of somatosensory evoked potentials (SSEP) is described. It is suitable for intraoperative monitoring of SSEP as well as for continuous recording in the intensive care unit. The principles of peak detection, the reliability of peak amplitude and latency measurements, and possibilities to reduce the complex information of evoked potentials to a few parameters are shown. As yet, there has been little clinical experience; however, in practice, a good applicability of the softeware could be shown.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Bertrand O, Garcia-Larrea L, Artru G, Mauguiere G, Pernier J (1987) Brain-stem monitoring. I. A system for high-rate sequential BAEP recording and feature extraction. Electroenceph Clin Neurophysiol 68: 433–445

    Article  PubMed  CAS  Google Scholar 

  • Billings FJ (1981) Automatic detection, measurement and documentation of the visual evoked potential using a commercial microprocessor-equipped averager. Electroenceph Clin Neurophysiol 52: 214–217

    Article  PubMed  CAS  Google Scholar 

  • Boston JR, Deneault LG (1984) Sensory evoked potentials: A system for clinical testing and patient monitoring. Int J Clin Monit Comput 1: 13–19

    Article  PubMed  CAS  Google Scholar 

  • Boston JR, Deneault LG, Kronk L, Jannetta PJ (1985) An automated monitoring of brainstem auditory evoked potentials in the operating room. J Clin Monit 1: 161–167

    Article  PubMed  CAS  Google Scholar 

  • Fridman J, John ER, Bergelson M, Kaiser JB, Baird HW (1982) Application of digital filtering and automatic peak detection to brain stem auditory evoked potential. Electroenceph Clin Neurophysiol 53: 405–416

    Article  PubMed  CAS  Google Scholar 

  • Friedman WA, Kaplan BL, Day AL, Sypert GW, Curran MT (1987) Evoked potential monitoring during aneurysm operation: Observations after fifty cases. Neurosurgery 20: 678–687

    Article  PubMed  CAS  Google Scholar 

  • Hume AL, Durkin MA (1986) Central and spinal somatosensory conduction times during hypothermic cardiopulmonary bypass and some observations on the effects of fentanyl and isoflurane anesthesia. Electroenceph Clin Neurophysiol 65: 46–58

    Article  PubMed  CAS  Google Scholar 

  • Little JR, Lesser RP, Lüders H (1987) Electrophysiological monitoring during basilar aneurysm operation. Neurosurgery 20: 421–427

    Article  PubMed  CAS  Google Scholar 

  • Markand ON, Warren CH, Moorthy SS, Stoelting RK, King RD (1984) Monitoring of multimodality evoked potentials during open heart surgery under hypothermia. Electroenceph Clin Neurophysiol 59: 432–440

    Article  PubMed  CAS  Google Scholar 

  • Prichep LS, John ER, Ransohoff J, Cohen N, Benjamin V, Ahn H (1985) Real-time intraoperative monitoring of cranal nerves VII and VIII during posterior fossa surgery. In: Morocutti C, Rizzo PA (eds) Evoked Potentials: Neurophysiological and Clinical Aspects. Elsevier, Amsterdam, pp 193–202

    Google Scholar 

  • Schwerdtfeger K, Ludt H (1986) Stainless steel skin staples — a useful electrode system for long-term electrophysiological measurements in neurosurgery. Acta Neurochir (Wien) 82: 137–140

    Article  CAS  Google Scholar 

  • Symon L, Momma F, Schwerdtfeger K, Bentivoglio P, Costa e Silva IE, Wang A (1986) Evoked potential monitoring in neurosurgical practice. In: Symon L (ed) Advances and Technical Standards in Neurosurgery. Vol 14. Springer, Wien, New York, pp 25–70

    Chapter  Google Scholar 

  • Walser H, Sutter M, Emre M (1987) Automatische Quantifizierung der SEP zur kontinuierlichen Patientenüberwachung. EEG EMG 17: 11–15

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1991 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Schwerdtfeger, K. (1991). An Automatic Peak Detection and Evaluation Program for Somatosensory Evoked Potential (SSEP) Monitoring. In: Schramm, J., Møller, A.R. (eds) Intraoperative Neurophysiologic Monitoring in Neurosurgery. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-75750-1_3

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-75750-1_3

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-75752-5

  • Online ISBN: 978-3-642-75750-1

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics