Skip to main content

A CCD Based Digital Detector for Whole-Breast Digital Mammography

  • Chapter
Digital Mammography

Abstract

We are developing an 18×27cm digital x-ray detector for whole-breast mammography based on CCD imaging technology [1]. In this paper we report the performance of a 10×20 cm, 2-CCD prototype we have built and tested. Similar to a film system, this detector uses a phosphor screen to convert an x-ray image to visible light. In the digital system the light photons are transferred onto a charge-coupled device (CCD) by a demagnifying fiber optic taper. Dedicated electronics then transfer the image to a PC based viewing station. The dynamic range of the detector is roughly 375 times greater than that of a typical screen film [2]. This difference increases our ability to discriminate low contrast differences in tissue, and allows image exposure to be determined solely by the desired signal-to-noise ratio and acceptable patient dose, whereas in a non-digital system, exposure is determined by film’s narrow linear response range.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. D. Rosen, M.J. Stanton, W. Phillips, M.B. Williams, D. O’Mara and H. Qian (1997) Full Field Digital Mammography Using CCD Technology, RSNA97, infoRAD Presentation

    Google Scholar 

  2. M.B. Williams, P.A. Mangiafico, P.U. Simoni, M.J. Stanton, W. Phillips, D. Rosen, (1997) Workstation Display of Images From a Prototype Detector for Digital Mammography, RSNA97, infoRAD Presentation

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1998 Springer Science+Business Media Dordrecht

About this chapter

Cite this chapter

Smilowitz, L. et al. (1998). A CCD Based Digital Detector for Whole-Breast Digital Mammography. In: Karssemeijer, N., Thijssen, M., Hendriks, J., van Erning, L. (eds) Digital Mammography. Computational Imaging and Vision, vol 13. Springer, Dordrecht. https://doi.org/10.1007/978-94-011-5318-8_5

Download citation

  • DOI: https://doi.org/10.1007/978-94-011-5318-8_5

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-94-010-6234-3

  • Online ISBN: 978-94-011-5318-8

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics