Skip to main content
  • 144 Accesses

Abstract

This chapter experimentally tests a proposed simplified online robust control strategy for practical applications to avoid the low delta-T syndrome for chilled water systems including complex systems. On top of the conventional control strategies, a temperature set-point reset scheme is developed aiming at providing the reliable temperature set-point for enhancing the operation reliability of chilled water pumps. In addition, a flow-limiting control scheme is employed to perform the function of actively eliminating the deficit flow in the bypass line by a feedback mechanism. The site test results show that the temperature set-point given by the proposed strategy is reliable and the system temperature difference is significantly raised by eliminating the deficit flow problem. When compared to the conventional control strategies, 78% of the total chilled water pump energy was saved in the test period. The actual pump energy saving percentage could be 39% in a year after implementing the robust control strategy in the studied system.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Gao, D. C., Wang, S. W., Sun, Y. J., & Xiao, F. (2012). Diagnosis of the low temperature difference syndrome in the chilled water system of a super high-rise building: A case study. Applied Energy, 98, 597–606.

    Article  Google Scholar 

  • Gao, D. C., Wang, S. W., Shan, K., & Yan, C. C. (2016). A system-level fault detection and diagnosis method for low delta-T syndrome in the complex HVAC systems. Applied Energy, 164, 1028–1038.

    Article  Google Scholar 

  • Wang, S. W., Gao, D. C., Sun, Y. J., & Xiao, F. (2013). An online adaptive optimal control strategy for complex building chilled water systems involving intermediate heat exchangers. Applied Thermal Engineering, 50, 614–628.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dian-Ce Gao .

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Singapore Pte Ltd.

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Gao, DC. (2019). Simplified Online Robust Pump Speed Control Strategy for Practical Implementation. In: Diagnosis and Robust Control of Complex Building Central Chilling Systems for Enhanced Energy Performance. Springer, Singapore. https://doi.org/10.1007/978-981-15-0698-7_7

Download citation

  • DOI: https://doi.org/10.1007/978-981-15-0698-7_7

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-15-0697-0

  • Online ISBN: 978-981-15-0698-7

  • eBook Packages: Physics and AstronomyPhysics and Astronomy (R0)

Publish with us

Policies and ethics