CT-Based Attenuation Correction for PET

  • Chapter
  • First Online:
Clinical PET-CT in Radiology
  • 2216 Accesses

Abstract

In order to perform attenuation correction in PET, the set of line integrals through the linear attenuation map at 511 keV corresponding to the geometry of the acquired PET data is needed. The fundamental step in CT-based attenuation correction is to use the CT images to generate the linear attenuation map at 511 keV. The use of PET-CT for cardiac applications, whether assessing myocardial viability or performing perfusion studies, requires a special consideration of the role of CT-based attenuation correction.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 199.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Levin CS, Hoffman EJ. Calculation of positron range and its effect on the fundamental limit of positron emission tomography spatial resolution. Phys Med Biol 1999;44:781–799.

    Article  CAS  PubMed  Google Scholar 

  2. Tarantola G, Zito F, Gerundini P. PET instrumentation and reconstruction algorithms in whole-body applications. J Nucl Med 2003;44:756–769.

    PubMed  Google Scholar 

  3. Hubbell JH. Review of photon interaction cross section data in the medical and biological context. Phys Med Biol 1999;44:R1–R22.

    Article  CAS  PubMed  Google Scholar 

  4. Keyes JW Jr. SUV: standard uptake value or silly useless value? J Nucl Med 1995;36:1836–1839.

    PubMed  Google Scholar 

  5. Zasadny KR, Wahl RL. Standardized uptake values of normal tissues at PET with 2-(fluorine-18)-fluoro-2-deoxy-D-glucose: variations with body weight and a method for correction. Radiology 1993;189:847–850.

    CAS  PubMed  Google Scholar 

  6. Kalender WA. Computed Tomography, 1st edn. Munich: Publicis MCD Verlag, 2000.

    Google Scholar 

  7. Hubbell JH, Seltzer SM. Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients from 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest. Natl Inst Stand Technol Rpt NISTIR 5632, 1995.

    Google Scholar 

  8. Kinahan PE, Townsend DW, Beyer T, et al. Attenuation correc­tion for a combined 3D PET/CT scanner. Med Phys 1998;25:2046–2053.

    Article  CAS  PubMed  Google Scholar 

  9. Burger C, Goerres G, Schoenes S, et al. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur J Nucl Med 2002;29:922-927.

    Article  CAS  Google Scholar 

  10. Heismann BJ, Leppert J, Stierstorfer K. Density and atomic number measurements with spectral x-ray attenuation method. J Appl Phys 2003;94:2073–2079.

    Article  CAS  Google Scholar 

  11. Schneider U, Pedroni E, Lomax A. The calibration of CT Hounsfield units for radiotherapy treatment planning. Phys Med Biol 1996;41:111–124.

    Article  CAS  PubMed  Google Scholar 

  12. Bai C, Shao L, Da Silva AJ, et al. A generalized model for the conversion from CT numbers to linear attenuation coefficients. IEEE Trans Nucl Sci 2003;50:1510–1515.

    Article  Google Scholar 

  13. Bailey DL. Transmission scanning in emission tomography. Eur J Nucl Med 1998;25:1–14.

    Article  Google Scholar 

  14. Beyer T, Kinahan PE, Townsend DW. Optimization of transmission and emission scan duration in 3D whole-body PET. IEEE Trans Nucl Sci 1997;44:2400–2407.

    Article  Google Scholar 

  15. Meikle SR, Dahlbom M, Cherry SR. Attenuation correction using count-limited transmission data in positron emission tomography. J Nucl Med 1993;34:143–150.

    CAS  PubMed  Google Scholar 

  16. Zaidi H, Diaz-Gomez M, Boudraa A, et al. Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging. Phys Med Biol 2002;47:1143–1160.

    Article  CAS  PubMed  Google Scholar 

  17. Holm S, Toft P, Jensen M. Estimation of the noise contributions from blank, transmission and emission scans in PET. IEEE Trans Nucl Sci 1996;43:2285–2291.

    Article  Google Scholar 

  18. Hsiao I-T, Gindi G. Noise propagation from attenuation correction into PET reconstructions. IEEE Trans Nucl Sci 2002;49:90–97.

    Article  Google Scholar 

  19. Dahlbom M, Hoffman EJ. Problems in signal-to-noise ratio for attenuation correction in high resolution PET. IEEE Trans Nucl Sci 1987;34:288–293.

    Article  Google Scholar 

  20. Goerres GW, Ziegler SI, Burger C, et al. Artifacts at PET and PET/CT caused by metallic hip prosthetic material. Radiology 2003;226:577–584.

    Article  PubMed  Google Scholar 

  21. Kamel EM, Burger C, Buck A, et al. Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner. Eur Radiol 2003;13:724–728.

    PubMed  Google Scholar 

  22. Antoch G, Freudenberg LS, Egelhof T, et al. Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans. J Nucl Med 2002;43:1339–1342.

    PubMed  Google Scholar 

  23. Carney JPJ, Beyer T, Brasse D, et al. CT-based attenuation correction for PET/CT scanners in the presence of contrast agent. 2002 IEEE Nuclear Science Symposium Conference Record 2003;3:1443–1446.

    Google Scholar 

  24. Visvikis D, Costa DC, Croasdale I, et al. CT-based attenuation correction in the calculation of semi-quantitative indices of [18F]FDG uptake in PET. Eur J Nucl Med 2003;30:344–353.

    Article  CAS  Google Scholar 

  25. Dizendorf E, Hany TF, Buck A, et al. Cause and magnitude of the error induced by oral CT contrast agent in CT-based attenuation correction of PET emission studies. J Nucl Med 2003;44:732–738.

    PubMed  Google Scholar 

  26. Nehmeh SA, Yusuf EE, Kalaigian H, et al. Correction for oral contrast artifacts in CT attenuation-corrected PET Images obtained by combined PET/CT. J Nucl Med 2003;44:1940–1944.

    PubMed  Google Scholar 

  27. Dizendorf EV, Treyer V, von Schulthess GK, et al. Application of oral contrast media in coregistered positron emission tomography-CT. Am J Roentgenol 2002;179:477–481.

    Google Scholar 

  28. Yau YY, Chan WS, Tam YM, et al. Application of intravenous contrast in PET/CT: does it really introduce significant attenuation correction error? J Nucl Med 2005;46:283–291.

    PubMed  Google Scholar 

  29. Bigger JT. Expanding indications for implantable cardiac defibrillators. N Engl J Med 2002;346:931–933.

    Article  PubMed  Google Scholar 

  30. Moss A, Zareba W, Hall W, et al.; Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 2002;346:877–883.

    Article  PubMed  Google Scholar 

  31. DiFilippo FP, Brunken RC. Do implanted pacemaker leads and ICD leads cause metal-related artifact in cardiac PET/CT? J Nucl Med 2005;46:436–443.

    PubMed  Google Scholar 

  32. Wilson JW, Wong TZ, Borges-Neto S, et al. An algorithm for correction of PET/CT mismatch induced cardiac attenuation correction artifacts. J Nucl Med 2005;46S(2):55P–56P.

    Google Scholar 

  33. Pan T, Mawlawi O, Nehmeh SA, et al. Attenuation correction of PET emission data with average CT for PET/CT. J Nucl Med 2005;46S(2):113P.

    Google Scholar 

  34. Hamill JJ, Carney JPJ, Faul DD, et al. Reduction of PET/CT attenuation correction artifacts due to implanted defibrillators. J Nucl Med 2005;46S(2):55P.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jonathan P. J. Carney .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer Science+Business Media, LLC

About this chapter

Cite this chapter

Carney, J.P.J. (2011). CT-Based Attenuation Correction for PET. In: Shreve, P., Townsend, D. (eds) Clinical PET-CT in Radiology. Springer, New York, NY. https://doi.org/10.1007/978-0-387-48902-5_4

Download citation

  • DOI: https://doi.org/10.1007/978-0-387-48902-5_4

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-0-387-48900-1

  • Online ISBN: 978-0-387-48902-5

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics