Abstract
It is proposed to employ a pulsed source of 14 MeV neutrons for in vivo activation analysis. This would permit the differentiation, with time, of the resulting gamma ray emission into three separate spectra, according to the type of nuclear reaction and mode of decay. The three-phase counting has been divided into ~ 10μs during “beam-on,” and 200 and 800μs during“beam-off” Measurement of the major elements, C, N, O, Cl, and P, to give nutritionally- important body compartments of total body fat, protein, water, minerals, and extracellular water, thus is expected with a single scan.
Author to whom all correspondence and reprint requests should be addressed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
A. H. Beddoe and G. L. Hill, J. Patenterai Enterai Nutrition 9, 504 (1985).
S. H. Cohn and R. M. Parr, Clin, Phys. Physiol. Meas. 6, 275 (1985).
D. R. Chettle and J. H. Fremiin, Phys. Med. Biol. 29, 1011 (1984).
A. H. Beddoe, S. J. Streat, and G. L. Hill Metabolism 33, 270 (1984).
K. Kyere, B. Oldrayd, C. B. Oxby, L. Burkinshaw, R. E. Ellis, and G. L. Hill, Phys. Med. Biol. 27, 805 (1982).
E. D. Williams and K. Boddy, Int. J. AppL Radiat. Isot. 29, 281 (1978).
B. W. East, T. Preston, I. Robertson, D. L. Davies, and G. Herd, In Vivo Body Composition Studies, K. J. Ellis, S. Yasumura, and W. D. Morgan, eds., IPSM, London, 1987, pp. 154–162.
A. H. Beddoe, H. Zuidmeer, and G. L. Hill, Phys. Med. Biol. 29, 371 (1984).
J. A. Auxier, W. S. Snyder, and T. D. Jones, Radiation Dosimetry, vol 1, 2nd edition, F. H. Attix and W. C. Roesch, eds., Academic, New York, 1968, p. 282.
J. J. Kehayias, K. J. Ellis, S. H. Cohn, S. Yasumura, and J. H. Weinlein, In Vivo Body Composition Studies, K. J. Ellis, S. Yasumura, and W. D. Morgan, eds., IPSM, London, 1987, pp. 427–435.
A. Sharafi, R Pearson, C. B. Oxby, B. Oldroyd, D. W. Krapowicz, K. Brooks, and R. E. Ellis, Phys. Med. Biol. 28, 203 (1983).
ICRP 1975, Report of the task group on reference man, Publication 23, Pergamon, Oxford.
R. G. Zamenhof, O. L. Deutsch, and B. W. Murray, Med. Phys. 6,179 (1979).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1990 Springer Science+Business Media New York
About this chapter
Cite this chapter
Mitra, S., Sutcliffe, J.F., Hill, G.L. (1990). A Proposed Three-Phase Counting System for the In Vivo Measurement of the Major Elements using Pulsed 14 MeV Neutrons. In: Zeisler, R., Guinn, V.P. (eds) Nuclear Analytical Methods in the Life Sciences. Humana Press, Totowa, NJ. https://doi.org/10.1007/978-1-4612-0473-2_46
Download citation
DOI: https://doi.org/10.1007/978-1-4612-0473-2_46
Publisher Name: Humana Press, Totowa, NJ
Print ISBN: 978-1-4612-6777-5
Online ISBN: 978-1-4612-0473-2
eBook Packages: Springer Book Archive