Skip to main content

Spatial Fourier Technique for Calibrating Gradiometers

  • Chapter
Advances in Biomagnetism

Abstract

One of the main features of the biomagnetic technique is the possibility to identify and locate sources of bioelectric activity with an uncertainty of a few millimeters. The use of multichannel systems not only eases this procedure shortening the time of the measurement session but also enables simultaneous measurement at different points in space, making possible the observation of non periodic phenomena. However, a multichannel system can introduce an important source of error in the localization result, if the calibration factor (field/voltage) of each channel is not measured with an extreme accuracy (Costa Ribeiro et al, 1988). The prospect of using planar gradiometers in biomagnetism imposes further difficulties to adapt the calibration procedures normaly used for axial gradiometers. In this work we propose a very general calibration method valid for all kinds of gradiometers and arrays. It is based on a spatial Fourier technique and in the fact that the gradiometer performs discrete spatial filtering.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Bruno, A.C., Paulsen, C.C., Symko, O., and Costa Ribeiro, P., 1988, Measurements of gradiometers’ spatial Transfer Function, in: ”Biomagnetism’87,” K. Atsumi, M. Kotani, S. Ueno, T. Katila and S.J. Williamson, eds., Tokyo Denki University Press, Tokyo.

    Google Scholar 

  • Costa Ribeiro, P., Williamson, S.J., and Kaufman, L., 1988, SQUID arrays for simultaneous magnetic measurements: Calibration and source localizations performance, IEEE Trans. Biomed. Eng., 35: 551.

    Article  PubMed  CAS  Google Scholar 

  • Knuutila, J., Ahlfors, S., Ahonen, A., Hallstron, J., Kajola, M., Lounasmaa, O.V., Vilkman, V., and Tesche, C., 1987, A Large-Area Low Noise Seven-Channel DC SQUID Magnetometer for Brain Research, Rev. Sci. Instrum., 58: 2145.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1989 Plenum Press, New York

About this chapter

Cite this chapter

Bruno, A.C., Dolce, C.S., Soares, S.D., Costa Ribeiro, P. (1989). Spatial Fourier Technique for Calibrating Gradiometers. In: Williamson, S.J., Hoke, M., Stroink, G., Kotani, M. (eds) Advances in Biomagnetism. Springer, Boston, MA. https://doi.org/10.1007/978-1-4613-0581-1_159

Download citation

  • DOI: https://doi.org/10.1007/978-1-4613-0581-1_159

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4612-7876-4

  • Online ISBN: 978-1-4613-0581-1

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics