A 6-year-old boy (20 kg) is admitted to hospital with a compound fracture of his right elbow after a fall from a tree. He has had lunch 1 h before admission. His history is otherwise unremarkable. As a 3-year-old, he underwent a tonsillectomy under general anesthesia without any problem. There is no adverse family history of anesthetic complications. On examination, the child is found to be otherwise healthy. Heart rate is 100 beats per minute (bpm). There is a low-grade systolic murmur at the apex. Blood pressure (BP) is 100/60 mmHg, and the chest is clear. The patient is taken to the operating room and all monitors are placed. General anesthesia is induced with propofol, 50 mg, and succinylcholine, 20 mg. Endotracheal intubation is performed with a No. 6 cuffed endotracheal tube (ETT). Breath sounds are equal bilaterally, and gastric breath sounds are not heard. The proximal end of the ETT is attached to a Bain system using the adapter on the Narkomed 2B machine. Anesthesia is maintained with intermittent boluses of fentanyl, vecuronium, and isoflurane 0.5–1.0 %. The fresh gas flow is 6 L (4 L of nitrous oxide and 2 L of oxygen). The lungs are mechanically ventilated using the ventilator on the Narkomed machine. Over a period of 30 min, you observe a gradual increase in end-tidal CO2 with minimal changes in vital signs. The tympanic and esophageal temperatures record a temperature of 36.1 °C. Bilateral air entry can still be heard, and no abnormal breath sounds are heard. The peak inspiratory pressure reading is 20 cm H2O and has not changed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Bain JA, Spoerel WE. A streamlined anaesthetic system. Can J Anaesth. 1972;19:426.

    Article  CAS  Google Scholar 

  2. Bain JA, Spoerel WE. Flow requirement for a modified Mapleson D system during controlled ventilation. Can J Anaesth. 1973;20:629.

    Article  CAS  Google Scholar 

  3. Lin YC, Brock-Utne JG. Pediatric anesthesia breathing system. Pediatr Anesth. 1996;6:1–5.

    Article  CAS  Google Scholar 

  4. Paterson JG, Vanhooydonk V. A hazard associated with improper connection of the Bain breathing circuit. Can J Anaesth. 1975;22:373.

    Article  CAS  Google Scholar 

  5. Hannallah R, Rosales JK. A hazard connected with re-use of the Bain’s circuit: a case report. Can J Anaesth. 1974;21:511.

    Article  CAS  Google Scholar 

  6. Foex P, Crampton-Smith A. A test for co-axial circuits. Anaesthesia. 1977;32:294.

    Article  Google Scholar 

  7. Heath PJ, Marks LF. Modified occlusion tests for the Bain breathing system. Anaesthesia. 1991;46:213–6.

    Article  PubMed  CAS  Google Scholar 

  8. Chard GA. Safety check for the Bain circuit. Can J Anaesth. 1984;31:487–8.

    Article  Google Scholar 

  9. Jackson IJB. Tests for co-axial systems. Anaesthesia. 1988;43:1060–1.

    Article  PubMed  CAS  Google Scholar 

  10. Robinson S, Fisher DM. Safety check for the CPRAM circuit. Anesthesiology. 1983;59:488–9.

    Article  PubMed  CAS  Google Scholar 

  11. Pethick SL. Correspondence. Can J Anaesth. 1975;22:115.

    Google Scholar 

  12. Petersen WC. Bain circuit. Can J Anaesth. 1978;25:532.

    Article  CAS  Google Scholar 

  13. Beauprie IG, Clark AG, Keith IC, Spence D. Pre-use testing of coaxial circuits: the perils of Pethick. Can J Anaesth. 1990;37:S103.

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer Science+Business Media New York

About this chapter

Cite this chapter

Brock-Utne, J.G. (2013). Case 39: Rising End-Tidal Carbon Dioxide. In: Near Misses in Pediatric Anesthesia. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-7040-3_39

Download citation

  • DOI: https://doi.org/10.1007/978-1-4614-7040-3_39

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4614-7039-7

  • Online ISBN: 978-1-4614-7040-3

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics