In-Situ Measurements of SF6 Leak Rates in Indoor Gas-Insulated Switchgears (GIS)

  • Chapter
Gaseous Dielectrics IX

Abstract

All SF6-insulated equipment leaks to some degree. These losses of SF6 gas are usually low and usually less than 2% of the whole gas content of typical GIS. They occur slowly and almost undetected for many years, until a low gas pressure alarm sounds. Over the last fifteen years, manufacturers have continuously improve the gas tightness of their metal-clad equipment which now exhibit leak rates roughly four time lower. Nevertheless, environmental concerns have been expressed in the last five years, peaking at the Kyoto meeting, about the cumulative effects of SF6 in the atmosphere. Remembering the PCB problems, electric utilities start evaluating their SF6 losses, since 80% of the SF6 gas lost into the air annually come from electrical equipment. At Hydro-Quebec, we realized an evaluation program aimed at the direct measurement of the SF6 leak rate of indoor GIS. Two substations were fitted with a sensitive SF6 trace analyzer and monitored during 9 and 13 months respectively, in two consecutive periods.SF6 gas was always present in the GIS surrounding air, at concentrations varying typically between 20 and ≈100 ppbv, but sometimes higher. These fluctuations were not due to the GIS leak rate changes but resulted mostly from the variations of the air exchange rate of the building due to external (climatic) and internal (heating, ventilation, human activities) factors. Interestingly, these measurements have shown that the two 20-years-old GIS studied exhibits average SF6 lost rates of only 0.55% or less.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2001 Springer Science+Business Media New York

About this chapter

Cite this chapter

Castonguay, J. (2001). In-Situ Measurements of SF6 Leak Rates in Indoor Gas-Insulated Switchgears (GIS). In: Christophorou, L.G., Olthoff, J.K. (eds) Gaseous Dielectrics IX. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-0583-9_75

Download citation

  • DOI: https://doi.org/10.1007/978-1-4615-0583-9_75

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4613-5143-6

  • Online ISBN: 978-1-4615-0583-9

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics