Abstract
Maxwell’s equations show that an accelerating electrical charge emits electromagnetic radiation. The emission of radio waves by electrons oscillating within an antenna is a familiar example of this effect. Electrons moving through a vacuum can be accelerated radially by a magnetic field oriented perpendicularly to their direction of motion. The high energy electrons circulating within a synchrotron experience a centripetal acceleration each time they pass through a bending magnet. Electrons whose path is bent by the magnetic field emit photons along the direction tangential to their path. Thus at each bending magnet around a synchrotron ring, radiation is emitted in a fan-shaped distribution; the limits of the “fan” are the directions of travel of the electrons before entering and after leaving the bending magnet. The radiation covers a very broad spectral range as shown in Fig. 1; this is the most important feature of synchrotron radiation.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Alpert, B., and Lopez-Delgado, R., 1976, Fluorescence lifetimes of haem proteins excited into the tryptophan absorption band with synchrotron radiation, Nature,263:445–446.
Blumberg, L. N., 1979, Vertical kicker for fluorescence decay experiments in the NSLS VUV ring, “BNL Report -26856”.
Brahms, S., and Brahms, J., 1980, Determination of protein secondary structure in solution by vacuum ultraviolet circular dichroism, J. Mol. Biol., 138:149–178.
Castellani, A., and Quercia, I. F., 1979, “Synchrotron radiation applied to biophysical and biochemical research”. Plenum Press, New York.
Ito, T., Kobayashi, K., and Ito, A., 1980, Effects of broad-band vacuum-UV synchrotron radiation on wet yeast cells, Radiation Research, 82:364–373.
Johnson, W. C. and Tinoco, I., 1972, Circular dichroism of polypeptide solutions in the vacuum ultraviolet, J. Am. Chem. Soc., 94:4389–4390.
Johnson, W. C., Jr., 1978, Circular dichroism spectroscopy and the vacuum ultraviolet region, Ann. Rev. Phys. Chem. in the press.
Munro, I., Pecht, I., and Stryer, L., 1979, Subnanosecond motions of tryptophan residues in proteins, Proc. Natl. Acad. Sci. U. S., 76:56–60.
Pysh, E. S., 1976, Optical activity in the vacuum ultraviolet, Ann. Rev. Biophys. Bioengr., 5:63–75.
Shulman, R. G., Eisenberger, P. and Kincaid, B. M., 1978, X-ray absorption spectroscopy of biological molecules,Ann. Rev. Biophys. Bioeng., 7:559–578.
Snyder, P. A. and Rowe, E. M., 1980, The first use of synchrotron radiation for vacuum ultraviolet circular dichroism measurements, Nuclear Instrumentation and Methods, in press.
Sprecher, C. A., Baase, W. A. and Johnson, W. C., Jr., 1979, Conformation and circular dichroism of DNA, Biopolymers, 18:1009–1019.
Wright, F., 1980, “Ultrasoft x-ray microscopy,” Annl. N. Y.Acad. Sci., 342.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1982 Plenum Press, New York
About this chapter
Cite this chapter
Sutherland, J.C. (1982). Synchrotron Radiation Sources for Photobiology and Ultraviolet, Visible and Infrared Spectroscopy. In: Hélène, C., Charlier, M., Montenay-Garestier, T., Laustriat, G. (eds) Trends in Photobiology. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-9203-7_2
Download citation
DOI: https://doi.org/10.1007/978-1-4615-9203-7_2
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4615-9205-1
Online ISBN: 978-1-4615-9203-7
eBook Packages: Springer Book Archive