Design Criteria for Medical Bragg Imaging

  • Chapter
Acoustical Holography
  • 121 Accesses

Abstract

We have built a Bragg imaging system using carefully designed cylindrical and spherical lenses essentially free of spherical aberrations. We are particularly interested in applying the system to medical applications and have therefore restricted ourselves to low frequencies of ultrasound (1–5 MHz). The system has been used to obtain transmitted and reflected images. In addition to images, quantitative data on the light intensity in the image as a function of sound intensity have been obtained, Engineering data on the optical mounting and transducer are also discussed.

The experience gained so far leads us ti believe that a well designed system will yield useful medical images.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. A. Korpel, “Visualization of the cross section of a sound beam by Bragg diffraction of laser light,” Appl. Phys. Letters 9(12): 425–427 (1966)

    Google Scholar 

  2. A.’Korpel, “Optical image of ultrasonic fields by acoustic Bragg diffraction,” Ph.D> dissertation, Ùniversity of Delft, Netherlands (1969).

    Google Scholar 

  3. R.A. Smith, G. Wade, J. Powers, 3. Landry, “Studies of resolution in a Bragg imaging system,” J. Acoust. Soc. Amer. 49: 1062–1068 (1971)

    Article  ADS  Google Scholar 

  4. J. Landry, H. Keyani, G. Wade, “Bragg-diffraction imaging: a potential technique for medical diagnosis and material inspection,” Acoustical Holography,;Vol. ÌV, Glen Wade ( Ed.) New York: Plenum Press (1972).

    Google Scholar 

  5. H. Keyani, J. Landr,y5 G. Wade, “Bragg-diffraction imaging. ‘a potential technique for medical diagnosis and material inspection, part II,” Acoustical Holography, Vol. V, Phiaip S. Green (Ed.), New York: Plenum Press (1974).

    Google Scholar 

  6. A. Korpel, “Astigmatic imaging properties of Bragg diffraction,” J. Acoust. Soc. of Amer. 49: 1059–1061 (1971).

    Article  ADS  Google Scholar 

  7. G. Flesher and G. Wade, Personal communication, University of California, Santa Barbara, November, 1975.

    Google Scholar 

  8. American Standard Procedures for Calibration of Electra-acoustic Transducers, American Standards Association Inc., New York (1958).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1977 Springer Science+Business Media New York

About this chapter

Cite this chapter

Frieda, D., Spiegler, P., Kearly, F., Greenfield, M., Stern, R. (1977). Design Criteria for Medical Bragg Imaging. In: Kessler, L.W. (eds) Acoustical Holography. Springer, Boston, MA. https://doi.org/10.1007/978-1-4757-0653-6_26

Download citation

  • DOI: https://doi.org/10.1007/978-1-4757-0653-6_26

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4757-0655-0

  • Online ISBN: 978-1-4757-0653-6

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics