Skip to main content

Clinical Use of Artificial Oxygen Carriers

  • Conference paper
Intensive Care Medicine
  • 332 Accesses

Abstract

Artificial oxygen carriers aim at improving oxygen delivery (DO2). Artificial oxygen carriers, therefore, may be used as an alternative to allogeneic blood transfusions or to improve tissue oxygenation and function of organs with marginal oxygen supply [1, 2]. Modified hemoglobin solutions and perfluorocarbon (PFC) emulsions are currently undergoing clinical testing. This chapter is based on a recent review article [3] where more detailed references may be found. Current knowledge of artifical oxygen carriers is based on published data from approximately 500–1000 patients treated with these compounds and a similar number of control patients. Unfortunately, there is still a significant amount of non-published data that renders the overall assessment of these solutions difficult.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Spahn DR, Pasch T (2001) Physiological properties of blood substitutes. News Physiol Sci 16: 38–41

    PubMed  CAS  Google Scholar 

  2. Winslow RM (2000) Blood substitutes. Advanced Drug Delivery Reviews 40: 131–142

    Article  PubMed  CAS  Google Scholar 

  3. Spahn DR, Kocian R (2003) Place of artifical oxygen carriers in reducing allogeneic blood transfusions and augmenting tissue oxygenation. Can J Anaesth (in press)

    Google Scholar 

  4. Stowell CP, Levin J, Spiess BD, Winslow RM (2001) Progress in the development of RBC substitutes. Transfusion 41: 287–299

    Article  PubMed  CAS  Google Scholar 

  5. Viele MK, Weiskopf RB, Fisher D (1997) Recombinant human hemoglobin does not affect renal function in humans: analysis of safety and pharmacokinetics. Anesthesiology 86: 848–858

    Article  PubMed  CAS  Google Scholar 

  6. Winslow RM (2000) Alpha-alpha-crosslinked hemoglobin: was failure predicted by preclinical testing? Vox Sang 79: 1–20

    Article  PubMed  CAS  Google Scholar 

  7. Sloan EP, Koenigsberg M, Gens D, et al (19999) Diaspirin cross-linked hemoglobin (DCLHb) in the treatment of severe traumatic hemorrhagic shock: a randomized controlled efficacy trial. JAMA 282: 1857–1864

    Google Scholar 

  8. Lamy ML, Daily EK, Brichant J-F, et al (2000) Randomized trial of Diaspirin cross-linked hemoglobin solution as an alternative to blood transfusion after cardiac surgery. Anesthesiology 92: 646–656

    Article  PubMed  CAS  Google Scholar 

  9. Gould SA, Moore EE, Hoyt DB, et al (1998) The first randomized trial of human polymerized hemoglobin as a blood substitute in acute trauma and emergent surgery. J Am Coll Surg 187: 113–120

    Article  PubMed  CAS  Google Scholar 

  10. Carmichael FJ, Biro GP, Cheng DC (2001) Phase III clinical trial of hemolink in conjunction with intraoperative autologous donation (IAD) in cardiac surgical patients. Artif Cells Blood Substit Immobil Biotechnol 29: 102 (abst)

    Google Scholar 

  11. Jahr JS (2001) A novel blood substitute: Use of HBOC-201 (Hemopure) to decrease need for RBC: Results of pivotal trail in orthopedic surgery patients. Crit Care Med 29 (suppl): A160 (abst)

    Google Scholar 

  12. Levy JH, Goodnough LT, Greilich P, et al (2002) Polymerized bovine hemoglobin solution as a replacement for allogeneic red blood cell transfusion after cardiac surgery: results of a randomized, double-blind trial. J Thorac Cardiovasc Surg 124: 35–42

    Article  PubMed  CAS  Google Scholar 

  13. Cheng DC, Martineau R, MacAdams C, et al (2001) Safety of Hemolink as an oxygen therapeutic in patients undergoing coronary artery bypass graft surgery. Anesth Analg 92 (suppl):SCA3 (abst)

    Google Scholar 

  14. Jahr JS, Stewart LM, MacKenzie C, Bourke D, williams JP (2002) Pivotal phase III study: safety of polymerized bovine hemoglobin (HBOC-201, Hemopure) as compared to RBC in patients undergoing orthopedic surgery. Anesthesiology 96: A243 (abst)

    Google Scholar 

  15. Sprung J, Kindscher JD, Wahr JA, et al (2002) The use of bovine hemoglobin glutamer-250 (Hemopure) in surgical patients: Results of a multicenter, randomized single-blind study. Anesth Analg 94: 799–808

    Article  PubMed  CAS  Google Scholar 

  16. Riess JG (2001) Oxygen carriers (“Blood substitutes”)–raison d’etre, chemistry, and some physiology. Chem Rev 101: 2797–2920

    Article  PubMed  CAS  Google Scholar 

  17. Keipert PE, Faithfull NS, Bradley JD, et al (1994) Oxygen delivery augmentation by low-dose perfluorochemical emulsion during profound normovolemic hemodilution. Adv Exp Med Biol 345: 197–204

    Article  PubMed  CAS  Google Scholar 

  18. Spahn DR, van Bremt R, Theilmeier G, et al (1999) Perflubron emulsion delays blood transfusion in orthopedic surgery. Anesthesiology 91: 1195–1208

    Article  PubMed  CAS  Google Scholar 

  19. Frumento RJ, Mongero LM, Naka Y, Bennett Guerrero E (2002) Preserved gastric tono-metric variables in cardiac surgical patients administered intravenous perflubron emulsion. Anesth Analg 94: 809–814

    Article  PubMed  CAS  Google Scholar 

  20. Spahn DR, Waschke K, Standl T, et al (2002) Use of perflubron emulsion to decrease allogeneic blood transfusion in high-blood loss non-cardiac surgery: results of a European phase 3 study. Anesthesiology 96: 1338–1349

    Article  Google Scholar 

  21. Looker D, Abbott-Brown D, Cozart P, et al (1992) A human recombinant haemoglobin designed for use as a blood substitute. Natue 356: 258–260

    Article  CAS  Google Scholar 

  22. Spahn DR (1999) Blood substitutes: artifical oxygen carriers: perfluorocarbon emulsions. Crit Care 3: R93 - R97

    Article  PubMed  CAS  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2003 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Dettori, N., Kocian, R., Spahn, D.R. (2003). Clinical Use of Artificial Oxygen Carriers. In: Vincent, JL. (eds) Intensive Care Medicine. Springer, New York, NY. https://doi.org/10.1007/978-1-4757-5548-0_58

Download citation

  • DOI: https://doi.org/10.1007/978-1-4757-5548-0_58

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4757-5550-3

  • Online ISBN: 978-1-4757-5548-0

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics