Abstract

Accurate and precise determinations of natural levels of trace metals in sea water are highly reliant upon the size and variability of the analytical blank, the method for determining the yield, and, to a lesser extent, the inherent precision of the instrument used. Thermal source, isotope dilution mass spectrometry together with ultra-clean room techniques were successfully used in the determinations of Cu, Cd, Pb, Zn, Ni and Fe in sea water. Multi-element analyses were performed in a single experiment owing to the differing release with filament current for each element. A single Re filament loaded with a substrate of silica gel and phosphoric acid gave high precision (0.1% to 0.5%) for the determination of a single ratio, and allowed low detection limits (from 0.02 fmol Cd to 0.07 pmol Fe). Yields were accurately and uniquely determined in the same sample by the addition of two isotopically enriched spikes, one before, and one after an extraction. Blanks were assessed as the summation of individual contributions determined in separate experiments prior to sample analysis. Simply obtaining one value for a total blank contribution can be misleading and can generate larger errors. Rigorous clean room procedures allowed very low blanks; 0.0002 nmol Cd kg−1, 0.0005-0.002 nmol Pb kg−1, 0.02 nmol Cu kg−1, 0.03 nmol Zn kg−1 and 0.7 nmol Fe kg−1.

Sea water, collected from relatively low-lead, coastal waters was stored acidified in rigorously cleaned, conventional polyethylene carboys at pH 2.0, pH 1.6 and at pH 1.1. Strict, clean room conditions allowed accurate comparisons to be made between carboys with varying PH’s of sample pretreatment and to the stability of the concentration with time. Extraction of sea water stored at pH 1.6 to 2.0 by dithizone and by APDC/DDDC in Freon TF yielded values representing the dissolved fraction. Acidification to pH 1.1 yielded higher Pb and Zn results but appeared insufficient for ‘total’ results as defined by aqua regia digestion of sea water. Isotopic composition work on Pb extracted or treated in the above manner supports the definition of soluble and total. The precision in the determination of soluble Cd and Zn with time was ca 1%, a level approaching that attained in measuring a single ratio. The Pb results were less precise, 5%, reflecting the low levels encountered, 0.04 nmol kg−1. Work at higher Pb concentrations indicated a much higher precision was possible. The determination of Cu, Ni and Fe were complicated by isobaric interferences. These could be minimized or eliminated by an ion-exchange purification of the final aqueous extract, and by a stabilization of the ratio with time and with filament current. Analysis of comparable amounts of Cd, Pb and Zn in NBS standard 1643a corroborated the accuracy of the IDMS approach/dithizone extraction procedure. Comparison of the sea water results with FAA and ASV methods indicated that for these metals, the IDMS approach was the most precise and the most accurate.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Chow, T.J., 1968: Isotope dilution analysis of sea water by mass spectrometry. Journal of WPCF, pp. 399–411.

    Google Scholar 

  2. Danielsson, L., B. Magnusson and S. Westerlund, 1978: An improved metal extraction procedure for the determination of trace metals in sea water by graphite furnace A.A. Anal. Chim. Acta., 98(1), 47–57.

    Article  Google Scholar 

  3. Garner, L.G. and L.P. Dunstan, 1978: Determination of nanogram per gram concentrations of iron by isotope dilution mass spectrometry. In: “Advances in Mass Spectrometry”, Vol. 7A, N.R. Daly, ed. Heydon and Sons, London, 481–485.

    Google Scholar 

  4. Moore, L.J., E.F. Heald and J.J. Filliben, 1978: An isotope fractionation model for the multiple filament thermal ion source. In: “Advances in Mass Spectrometry”, Vol. 7A, N.R. Daly, ed. Heydon and Sons, London, 448–474.

    Google Scholar 

  5. Murozumi, M., 1979: Isotope dilution mass spectrometry of copper, cadmium, thallium and lead in marine environments. Presented at ACS/CSJ Chemical Congress, Hawaii.

    Google Scholar 

  6. Mykytiuk, A.P., D.S. Russell and R.E. Sturgeon, 1980: Simultaneous determination of iron, cadmium, zinc, copper, nickel, lead and uranium in sea water by stable isotope dilution spark source mass spectrometry. Anal. Chem., 52, 1281–1283.

    Google Scholar 

  7. Patterson, C.C. and D.M. Settle, 1976: The reduction of orders of magnitude errors in lead analyses of biological materials and natural waters by evaluating and controlling the extent and sources of industrial lead contamination introduced during sample collecting, handling and analysis. NBS spec. pub. 422, 321–351.

    Google Scholar 

  8. Patterson, C.C., D.M. Settle and B. Glover, 1976: Analysis of lead in polluted coastal sea water. Mar. Chem., 4, 305–319.

    Article  Google Scholar 

  9. Schaule, B. and C.C. Patterson, 1980: The occurrence of lead in the Northeast Pacific, and the effects of anthropogenic inputs. In: “Lead in the Marine Environment”, M. Brancia and Z. Konrad, eds. Pergamon Press, Oxford, 31–43.

    Google Scholar 

  10. Smith, R.G., Jr. and H.L. Windom, 1980: A solvent extraction technique for determining nanogram per litre concentrations of cadmium, copper, nickel and zinc in sea water. Anal. Chim. Acta., 113, 39–46.

    Article  Google Scholar 

  11. Stukas, V.J. and C.S. Wong, 1981: Stable lead isotopes as a tracer in coastal waters. Science, 211, 1424–1427.

    Google Scholar 

  12. Sturgeon, R.E., S.S. Berman, A. Desaulniers and D.S. Russell, 1980: Preconcentration of trace metals from sea water for determination by graphite furnace atomic absorption spectrophotometry. Talanta, 17, 85–94.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1983 Springer Science+Business Media New York

About this chapter

Cite this chapter

Stukas, V.J., Wong, C.S. (1983). Accurate and Precise Analysis of Trace Levels of Cu, Cd, Pb, Zn, Fe and Ni in Sea Water by Isotope Dilution Mass Spectrometry. In: Wong, C.S., Boyle, E., Bruland, K.W., Burton, J.D., Goldberg, E.D. (eds) Trace Metals in Sea Water. NATO Conference Series, vol 9. Springer, Boston, MA. https://doi.org/10.1007/978-1-4757-6864-0_31

Download citation

  • DOI: https://doi.org/10.1007/978-1-4757-6864-0_31

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4757-6866-4

  • Online ISBN: 978-1-4757-6864-0

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics