Abstract
The present study was aimed to characterize 3-dimensional (3D) morphology of the cortical microvasculature (e.g., penetrating artery and emerging vein), using two-photon microscopy and automated analysis for their cross-sectional diameters and branching positions in the mouse cortex. We observed that both artery and vein had variable cross-sectional diameters across cortical depths. The mean diameter was similar for both artery (17 ± 5 μm) and vein (15 ± 5 μm), and there were no detectable differences over depths of 50–400 μm. On the other hand, the number of branches was slightly increased up to 400-μm depth for both the artery and vein. The mean number of branches per 0.1 mm vessel length was 1.7 ± 1.2 and 3.8 ± 1.6 for the artery and vein, respectively. This method allows for quantification of the large volume data of microvascular images captured with two-photon microscopy. This will contribute to the morphometric analysis of the cortical microvasculature in functioning brains.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Zilles K, Wree A (1995) Cortex: areal and laminar structure. In: Paxinos G (ed) The rat nervous system, 2nd edn. Acadmic Press, San Diego, pp 649–685
Masamoto K, Tanishita K (2009) Oxygen transport in brain tissue. J Biomech Eng 131:7, 074002
Yoshihara K, Takuwa H, Kanno I, Okawa S, Yamada Y, Masamoto K (2013) 3D analysis of intracortical microvasculature during chronic hypoxia in mouse brains. Adv Exp Med Biol 765:357–363
Tomita Y, Kubis N, Calando Y, Tran Dinh A, Méric P, Seylaz J, Pinard E (2005) Long-term in vivo investigation of mouse cerebral microcirculation by fluorescence confocal microscopy in the area of focal ischemia. J Cereb Blood Flow Metab 25(7):858–867
Masamoto K, Tomita Y, Toriumi H, Aoki I, Unekawa M, Takuwa H, Itoh Y, Suzuki N, Kanno I (2012) Repeated longitudinal in vivo imaging of neuro-gliovascular unit at the peripheral boundary of ischemia in mouse cerebral cortex. Neuroscience 212:190–200
Sekiguchi Y, Masamoto K, Takuwa H, Kawaguchi H, Kanno I, Ito H, Tomita Y, Itoh Y, Suzuki N, Sudo R, Tanishita K (2013) Measuring the vascular diameter of brain surface and parenchymal arteries in awake mouse. Adv Exp Med Biol 789:419–425
Woolsey TA, Rovainen CM, Cox SB, Henegar MH, Liang GE, Liu D, Moskalenko YE, Sui J, Wei L (1996) Neuronal units linked to microvascular modules in cerebral cortex: response elements for imaging the brain. Cereb Cortex 6:647–660
Acknowledgments
This study was partially supported through funding from JSPS KAKENHI (#25750400) (to K.M.), JSPS KEKENHI (#24659578) (to I.K.), and a grant from the Ministry of Health, Labor and Welfare (MHLW), Japan (to I.K.).
Author information
Authors and Affiliations
Corresponding authors
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer Science+Business Media, LLC
About this paper
Cite this paper
Sugashi, T. et al. (2014). Automated Image Analysis for Diameters and Branching Points of Cerebral Penetrating Arteries and Veins Captured with Two-Photon Microscopy. In: Swartz, H.M., Harrison, D.K., Bruley, D.F. (eds) Oxygen Transport to Tissue XXXVI. Advances in Experimental Medicine and Biology, vol 812. Springer, New York, NY. https://doi.org/10.1007/978-1-4939-0620-8_28
Download citation
DOI: https://doi.org/10.1007/978-1-4939-0620-8_28
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4939-0583-6
Online ISBN: 978-1-4939-0620-8
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)