Pulse Arrival Time Techniques

  • Chapter
  • First Online:
The Handbook of Cuffless Blood Pressure Monitoring

Abstract

For over 90 years, researchers and clinicians have worked on systems to noninvasively measure pulse wave velocity, with the ultimate goal of measuring continuous, cuffless blood-pressure. The design of multisensor systems to make two or more measurements of the pulse wave along the human arterial tree has become the hallmark of these efforts. Pulse arrival time measurements are traditionally made by detecting a first fiducial point on the electrocardiogram (ECG) waveform, and second fiducial point on a distal pulsatile waveform, such as the photoplethysmogram (PPG) or impedance cardiogram (ICG). By looking at the time difference between these two fiducial points, an approximation for pulse wave velocity can be calculated. Some other challenges exist in transforming the pulse arrival times into absolute blood pressure, but these have been largely overcome, as evidenced by the clinical-grade systems that are commercially available in the marketplace today.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 199.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 199.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Mukkamala R, Hahn JO, et al. Toward ubiquitous blood pressure monitoring via pulse transit time: theory and practice. IEEE Trans Biomed Eng. 2015;62(8):1879–901.

    Article  Google Scholar 

  2. Teng XF, Zhang YT. The effect of applied sensor contact force on pulse transit time. Physiol Meas. 2006;27:675.

    Article  CAS  Google Scholar 

  3. Bang S, et al. A pulse transit time measurement method based on electrocardiography and bioimpedance. In: 2009 IEEE Biomedical Circuits and Systems Conference. 2009. p. 153–6.

    Google Scholar 

  4. Patterson R. Fundamentals of impedance cardiography. IEEE Eng Med Biol Mag. 1989;8:35–8.

    Article  CAS  Google Scholar 

  5. Inan OT, et al. Robust ballistocardiogram acquisition for home monitoring. Physiol Meas. 2009;30:169.

    Article  CAS  Google Scholar 

  6. Payne RA, et al. Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure. J Appl Physiol. 2006;100:136–41.

    Article  CAS  Google Scholar 

  7. Zhang G, et al. Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure. J Appl Physiol. 2011;111:1681–6.

    Article  Google Scholar 

  8. McCombie DB, et al. Motion based adaptive calibration of pulse transit time measurements to arterial blood pressure for an autonomous, wearable blood pressure monitor. Conf Proc IEEE Eng Med Biol Soc. 2008;2008:989–92.

    PubMed  Google Scholar 

  9. Perloff D, et al. Human blood pressure determination by sphygmomanometry. Circulation. 1993;88:2460–70.

    Article  CAS  Google Scholar 

  10. Alpert BS, et al. Oscillometric blood pressure: a review for clinicians. J Am Soc Hypertens. 2014;8:930–8.

    Article  Google Scholar 

  11. Hickson SK, McSwiney BA. The effect of variation in blood pressure on pulse wave velocity in the brachial artery in man. J Physiol. 1924;59:217–20.

    Article  CAS  Google Scholar 

  12. Thomas JG. A method for continuously indicating blood pressure. J Physiol. 1955;129(3):75–6P.

    CAS  PubMed  Google Scholar 

  13. Weltman G, Sullivan G, Bredon D. The continuous measurement of arterial pulse wave velocity. Med Electron Biol Eng. 1964;2:145–54.

    Article  CAS  Google Scholar 

  14. “Innovative Technologies”, Nihon Kohden. https://ae.nihonkohden.com/en/innovativetechnologies/pwtt.

  15. “Why Visi”, Sotera Wireless. https://www.soterawireless.com/why-visi/.

  16. “Somnotouch NIBP”, Somnomedics. https://somnomedics.eu/products/cardiology/24h-bloodpressure-24h-ecg/somnotouch-nibp/.

  17. “Pulse Transit Time (PTT), Pulse Wave Velocity (PWV), and Pulse Wave Amplitude (PWA)”, Biopac. https://www.biopac.com/application/plethysmography/advanced-feature/pulse-transit-time-ptt-and-relative-bp-measurement/.

  18. “CheckMe Pro”, Viatom. https://www.viatomtech.com/checkme-pro.

  19. “Features”, Care Up. http://care-up.com/.

  20. “H2-BP”, H2 Care. http://h2care.com/18.

  21. Chandrasekhar A, Kim CS, Naji M, Natarajan K, Hahn JO, Mukkamala R. Smartphone-based blood pressure monitoring via the oscillometric finger-pressing method. Sci Transl Med. 2018;10(431):eaap8674.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Matthew J. Banet .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Dhillon, M.S., Banet, M.J. (2019). Pulse Arrival Time Techniques. In: Solà, J., Delgado-Gonzalo, R. (eds) The Handbook of Cuffless Blood Pressure Monitoring. Springer, Cham. https://doi.org/10.1007/978-3-030-24701-0_5

Download citation

Publish with us

Policies and ethics