Abstract

Complex injuries are not optimally treatable with standard medical methods, especially when joints or articular surfaces are affected. To achieve an intact and functional joint, the articular surface covered by hyaline cartilage must be restored geometrically correct. Since hyaline cartilage has a poor ability to regenerate, a damaged articular surface requires replacement. This article describes the CAE-assisted preoperative planning of the reconstruction of a defective proximal interphalangeal joint surface. While determining needed medical aids, optimization potentials for existing external fixators have additionally been detected. In the following, the development of an adapted finger fixator with extended pre-, intra- and postoperative adjustment possibilities will be explained. The optimized fixator therefore requires less intraoperative precision. Possible inaccuracies during the surgery can be eliminated due to the adjustment possibilities afterwards. Likewise, it is possible to respond to changing anatomical conditions during the healing process, which grants a greater chance of rehabilitation overall. The basic design and material selections for the fixator are defined through the usage of numerical methods. Subsequently, the reliability is tested by using experimental methods.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Erdogan, A., Weiss, A.P.C.: Metakarpophalangeale Arthroplastik mit der NeuFlex-Silastikprothese. Der Orthopäde 32(9), 789–793 (2003)

    Article  CAS  Google Scholar 

  2. Schindele, S.F., Hensler, S., Audigé, L., Marks, M., Herren, D.B.: A modular surface gliding implant (CapFlex-PIP) for proximal interphalangeal joint osteoarthritis: a prospective case series. J. Hand Surg. 40(2), 334–340 (2015)

    Article  Google Scholar 

  3. Schindele, S.F., Sprecher, C.M., Milz, S., Hensler, S.: Osteointegration of a modular metal-polyethylene surface gliding finger implant: a case report. Arch. Orthop. Trauma Surg. 136(9), 1331–1335 (2016)

    Article  Google Scholar 

  4. Buchner, H.J., Hines, M.J., Hemami, H.: A dynamic model for finger interphalangeal coordination. J. Biomech. 21(6), 459–468 (1988)

    Article  CAS  Google Scholar 

  5. Holguín, P.H., Rico, Á.A., Gómez, L.P., Munuera, L.M.: The coordinate movement of the interphalangeal joints – a cinematic study. Clin. Orthop. Relat. Res. 362, 117–124 (1999)

    Google Scholar 

  6. Loubert, P.V., Masterson, T.J., Schroeder, M.S., Mazza, A.M.: Proximity of collateral ligament origin to the axis of rotation of the proximal interphalangeal joint of the finger. J. Orthop. Sports Phys. Ther. 337(4), 179–185 (2007)

    Article  Google Scholar 

  7. Hess, F., Fürnstahl, P., Gallo, L.M., Schweizer, A.: 3D analysis of the proximal interphalangeal joint kinematics during flexion. Comput. Math. Methods Med. 2013(362), 138063 (2013)

    PubMed  PubMed Central  Google Scholar 

  8. ASTM F1541-17: Standard Specification and Test Methods for External Skeletal Fixation Devices. ASTM International, West Conshohocken, PA (2017)

    Google Scholar 

  9. Verein Deutscher Ingenieure: VDI-Richtlinie 2221 – Methodik zum Entwickeln und Konstruieren technischer Systeme und Produkte. Beuth Verlag, Berlin (1993)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Lena Risse .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Risse, L., Woodcock, S.C., Kullmer, G., Schramm, B., Richard, H.A. (2019). Reconstruction of a Defective Finger Joint Surface and Development of an Adapted External Fixator. In: Tavares, J., Natal Jorge, R. (eds) VipIMAGE 2019. VipIMAGE 2019. Lecture Notes in Computational Vision and Biomechanics, vol 34. Springer, Cham. https://doi.org/10.1007/978-3-030-32040-9_24

Download citation

Publish with us

Policies and ethics