High-rise mass timber buildings with CLT and glulam are being planned and constructed within the globally. As timber buildings are constructed taller, architects and building owners are requesting more timber be exposed. High-rise buildings are required to have fire resistance ratings for the structural elements that can withstand the design fire in the highly unlikely event of a fully developed fire. Addressing how exposed timber and in particular CLT, influences a fully developed fire through to fire extinguishment is a current fire safety issue. The fire heat release rate and fire duration will be increased due to the added combustible fuel available from the exposed timber, when compared to a compartment without any exposed timber, once all the fixtures and furnishings have been consumed. Existing fire test data shows that large areas of exposed timber has a significant impact on heat release rate, but limited areas of exposed timber can be accommodated within a fire safe design. To design a compartment with exposed timber requires an understanding of the susceptibility of the CLT to char fall off and the expected fire duration due to the area and location of the exposed timber.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
https://www.woodsolutions.com.au/Inspiration-Case-Study/forte-living
http://www.naturallywood.com/emerging-trends/tall-wood-buildings/ubc-brock-commons
Su J, LaFrance P, Hoehler M, Bundy M (2018) Fire safety challenges of tall wood buildings – phase 2: task 2 & 3 cross laminated timber compartment fire tests. Fire Protection Research Foundation, Report No. FPRF-2018-01
Frangi A, et al (2008) Fire behaviour of cross-laminated solid timber panels. Institute of Structural Engineering, ETH Zurich, Zurich, Switzerland
Klippel M (2014) Fire safety of bonded structural timber elements. ETH Zurich, Institute of Structural Engineering, thesis number 359
Crielaard R (2015) Self-extinguishment of cross-laminated timber, thesis, Delft University of Technology, Netherlands
Barber D, Crielaard R, Li X (2016) Towards fire safe design of exposed timber in tall timber buildings. In: Proceedings of the world conference of timber engineering, 22–25 August 2016, Vienna
Brandon D, Dagenais C (2018) Fire safety challenges of tall wood buildings – phase 2: task 5 - experimental study of delamination of cross laminated timber (CLT) in fire. Fire Protection Research Foundation, report no. FPRF-2018–05
Karacabeyli E, Douglas B (2013) CLT handbook, US edition FPInnovations SP529-E
ANSI/APA (2018) PRG-320 standard for performance-rated cross-laminated timber
American Society for Testing and Materials (2016) ASTM E119: standard test methods for fire tests of building construction and materials
Frangi A, Fontana M (2005) Fire performance of timber structures under natural fire conditions. In: Fire safety science – proceedings of the eighth international symposium, pp 279–290
Hakkarainen T (2002) Post-flashover fires in light and heavy timber construction compartments. J Fire Sci 20:133–175. https://doi.org/10.1177/0734904102020002074
McGregor C (2013) Contribution of cross laminated timber panels to room fires, thesis. Carleton University, Ottawa, Canada
Medina A (2014) Fire resistance of partially protected CLT rooms, thesis. Carleton University, Ottawa, Canada
Hadden R, Bartlett A, Hidalgo J, Santamaria S, Wiesner F, Bisby L, Deeny S, Lane B (2017) Effects of exposed engineered timber on compartment fire dynamics. In: Proceedings of the 12th international association of fire safety science symposium, Lund, 10 June to 16 2017
Hox K (2015) Branntest av massivtre SP fire research, report A15101 (in Norwegian, translated by Arup)
Emberley R, Gorska C, Bolanosa A, Lucherinia A, Solartea A, Soriguera D, Gutierrez M, Humphreys K, Hidalgoa J, Maluka C, Law A, Torero J (2017) Description of small and large-scale cross laminated timber fire tests. Fire Saf J 91:327–335
Zelinka S, Hasburgh L, Bourne K, Tucholski D, Ouellette J (2018) Compartment fire testing of a two-story mass timber building. General technical report FPL–GTR–247, May 2018
Just A, Brandon D, Nele Mäger K, Pukk R, Sjöström J, Kahl F (2018) CLT compartment fire test. In: Proceedings of world conference on timber engineering, 20–22 August 2018, Seoul
Su J, Leroux P, Lafrance P, Berzins R, Gratton K, Gibbs E, Weinfurter M (2018) Fire testing of rooms with exposed wood surfaces in encapsulated mass timber construction. National Research Council, Canada report no. A1-012710.1
Buchanan A (2001) Structural design for fire safety. Wiley, Hoboken
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Barber, D., Dixon, R., Deeny, S., Steenbakkers, P. (2020). Issues and Solutions for Compartments with Exposed Structural Mass Timber Elements. In: Makovicka Osvaldova, L., Markert, F., Zelinka, S. (eds) Wood & Fire Safety. WFS 2020. Springer, Cham. https://doi.org/10.1007/978-3-030-41235-7_32
Download citation
DOI: https://doi.org/10.1007/978-3-030-41235-7_32
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-41234-0
Online ISBN: 978-3-030-41235-7
eBook Packages: EngineeringEngineering (R0)