Abstract
Repetitive ignitions of electric arc during switching operation may result in generating Fast and Very Fast Transients (FT and VFT) and thus require analyses to ensure reliable system operation. The paper presents a common approach for modeling and simulation of such phenomenon for two types of switching devices: Vacuum Circuit Breakers (VCB) and GIS disconnectors. In each case, the associated (VFT) are modeled with the use of a case-specific Breakdown Voltage Characteristic (BDV), characterizing the switching process, and with the use of case-specific power system conditions. Two case studies are presented. For Vacuum Circuit Breaker, a switching operation of un-loaded transformer is presented. For GIS disconnector, switching of short bus-bar during the disconnector type testing is presented.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
CIGRE JWG A2–A3–B3.21 (2005) Electrical environment of transformers—impact of fast transients. Electra 218:25–37
IEEE PC57.142/D8.3 (2012) Guide to describe the occurrence and mitigation of switching transients induced by transformer, switching device, and system interaction. IEEE PES Transformers Committee and the Switchgear Committee, WG
Riechert U, Bösch M, Smajic J, Shoory A, Szewczyk M, Piasecki W, Burow S, Tenbohlen S (2012) Mitigation of very fast transient overvoltages in gas insulated UHV substations. CIGRE
Helmer J, Lindmayer M (1996) Mathematical modeling of the high frequency behavior of vacuum interrupters and comparison with measured transients in power systems. IEEE 17th International Symposium on Discharges and Electrical Insulation in Vacuum, Berkeley
Wong SM, Snider LA, Lo EWC (2003) Overvoltages and reignition behaviour of vacuum circuit breaker. International Conference on Power Systems Transients (IPST), New Orleans, USA
Dommel HW, Meyer WS (1974) Computation of electromagnetic transients. Proc IEEE 62(7):983–993
Povh D, Schmitt H, Volcker O et al. (1996) Modeling and analysis guidelines for very fast transients. IEEE Power Eng Rev 17(13)
IEC 62271-102 (2013) High-voltage switchgear and controlgear—Part 102: alternating current disconnectors and earthing switches
Szewczyk M, Piasecki W, Stosur M, Riechert U, Kostovic J (2011) Impact of disconnector design on very fast transient overvoltages in gas-insulated UHV switchgear. In: Proceedings of 17th International Symposium on High Voltage Engineering (ISH), Hannover, Germany. 22–26 Aug 2011
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer International Publishing Switzerland
About this paper
Cite this paper
Szewczyk, M., Kuczek, T., Oramus, P., Piasecki, W. (2015). Modeling of Repetitive Ignitions in Switching Devices: Case Studies on Vacuum Circuit Breaker and GIS Disconnector. In: Gołębiowski, L., Mazur, D. (eds) Analysis and Simulation of Electrical and Computer Systems. Lecture Notes in Electrical Engineering, vol 324. Springer, Cham. https://doi.org/10.1007/978-3-319-11248-0_18
Download citation
DOI: https://doi.org/10.1007/978-3-319-11248-0_18
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-11247-3
Online ISBN: 978-3-319-11248-0
eBook Packages: EngineeringEngineering (R0)