Skip to main content

3D Reconstruction of Tubular Structures from Three Orthogonal MRI Projections

  • Conference paper
  • First Online:
XIV Mediterranean Conference on Medical and Biological Engineering and Computing 2016

Part of the book series: IFMBE Proceedings ((IFMBE,volume 57))

Abstract

This study presents a novel method for 3D imaging of tubular structures, such as blood vessels and catheters. With this method, the 3D object is reconstructed from three mutually exclusive orthogonal projections of the same volume. This triplanar projection imaging (TPI) was evaluated on a phantom filled with T1-shortening, Gd-based contrast agent embedded into a matrix. The projected structures were segmented out on each one of the projections and a backprojection algorithm was used to generate a rendering of the tubular structure in 3D. The accuracy of the method was investigated by comparing the centerline of the 3D tubular structure generated from TPI with the centerline extracted from a multislice set of images of the same volume. The two tubular structures were well matched in 3D. With further optimization and reduction of acquisition time, this method can be used for 3D fast imaging of interventional tools or blood vessels with applications in interventional MRI.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Tsekos NV, Shudy J, Yacoub E et al. (2001) Development of a robotic device for MRI-guided interventions in the breast, Proc. IEEE Int Symp Bioinform Bioeng pp. 201-208

    Google Scholar 

  2. Tsekos NV, Ozcan A, Christoforou E. (2005) A prototype manipulator for magnetic resonance-guided interventions inside standard cylindrical magnetic resonance imaging scanners. J Biomech Eng 127 (6):972-80

    Google Scholar 

  3. Baert SA, van de Kraats EB, van Walsum T et al. (2003) Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature. IEEE Trans Med Imaging 22 (10):1252-8

    Google Scholar 

  4. Bender HJ, Manner R, Poliwoda C et al. (1999) Reconstruction of 3D Catheter Paths from 2D X-ray Projections, Proc. MICCAI vol. 1679, pp. 981-989

    Google Scholar 

  5. Solaiyappan M, Lee J, Atalar E. (1999) Depth Reconstruction from Projection Images for 3D Visualization of Intravascular MRI Probes, Proc. ISMRM

    Google Scholar 

  6. Sathyanarayana S, Aksit P, Arepally A et al. (2007) Tracking planar orientations of active MRI needles. J Magn Reson Imaging 26(2):386-391

    Google Scholar 

  7. George AK, Derbyshire JA, Saybasili H et al. (2010) Visualization of active devices and automatic slice repositioning (“SnapTo”) for MRI-guided interventions. Magn Reson Med 63(4):1070-9

    Google Scholar 

  8. Schirra CO, Weiss S, Krueger S et al. (2010) Accelerated 3D catheter visualization from triplanar MR projection images. Magn Reson Med 64(1):167-76

    Google Scholar 

  9. Polesel A, Ramponi G, Mathews VJ (2000) Image enhancement via adaptive unsharp masking, IEEE Transactions on Image Processing, vol. 9, pp. 505-510

    Google Scholar 

  10. Chaudhuri S, Chatterjee S, Katz N et al. (1989) Detection of blood vessels in retinal images using two-dimensional matched filters, IEEE Transactions on Medical Imaging, vol. 8, pp. 263-269

    Google Scholar 

  11. Mukherjee S, Acton S (2015) Region Based Segmentation in Presence of Intensity Inhomogeneity Using Legendre Polynomials, IEEE Signal Processing Letters, vol. 22, issue 3, pp. 298-302

    Google Scholar 

  12. Lorensen WE, Cline HE (1987) Marching Cubes: A High Resolution 3D Surface Construction Algorithm, Proc. SIGGRAPH vol. 21, pp. 163-169

    Google Scholar 

  13. Huang H, Wu S, Cohen-Or D et al. (2013) L1-Medial Skeleton of Point Cloud, Proc. SIGGRAPH vol. 32, pp. 65:1-8

    Google Scholar 

  14. Christoforou E, Akbudak E, Ozcan A et al. (2007) Performance of interventions with manipulator-driven real-time MR guidance: implementation and initial in vitro tests. Magn Reson Imaging 25(1):69-77

    Google Scholar 

  15. Yamashita Y, Abe Y, Tang Y, Urata J et al. (1997) In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique. AJR Am J Roentgenol 168(6):1449-54

    Google Scholar 

  16. Atalar E, Kraitchman DL, Carkhuff B et al. (1998) Catheter-Tracking FOV MR Fluoroscopy. Magn Reson Med 40(6):865-72

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nikolaos V. Tsekos .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer International Publishing Switzerland

About this paper

Cite this paper

An, J. et al. (2016). 3D Reconstruction of Tubular Structures from Three Orthogonal MRI Projections. In: Kyriacou, E., Christofides, S., Pattichis, C. (eds) XIV Mediterranean Conference on Medical and Biological Engineering and Computing 2016. IFMBE Proceedings, vol 57. Springer, Cham. https://doi.org/10.1007/978-3-319-32703-7_64

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-32703-7_64

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-32701-3

  • Online ISBN: 978-3-319-32703-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics