Skip to main content

ASD Closure in Special Situations: Elderly, PA-IVS

  • Chapter
  • First Online:
Atlas of Cardiac Catheterization for Congenital Heart Disease

Abstract

Transcatheter closure is nowadays considered as the first-choice treatment of atrial septal defect (ASD). However, indication, technique, and results of this approach are still challenging and under debate in particular settings, as in elderly or in patients with pulmonary atresia with intact ventricular septum (PA-IVS) submitted to right ventricular decompression.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 189.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 249.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

1 Electronic Supplementary Material

Temporary ASD balloon occlusion in elderly patient to size the defect as well as to evaluate any hemodynamic change resulting from the sudden left-to-right shunt disappearance. The occluding balloon is inflated into the right atrium and carefully advanced to the atrial septum until the shunt disappears, as evaluated at color Doppler analysis (MP4 4507 kb)

Step-by-step description of percutaneous ASD closure as imaged at fluoroscopy. After ASD sizing, the left disk and the central waist of the device are sequentially opened in the left atrium and carefully approached to the atrial septum. As soon as the central waist fills the atrial septal defect, the right disk of the device is deployed in order to stabilize the device. Then, a “push and pull” maneuver is performed to test the device stability. Finally, the device is released (MP4 14243 kb)

Bidirectional shunt at atrial level in a patient with PA-IVS previously submitted to RV decompression by pulmonary valve perforation and angioplasty, as imaged at TEE color Doppler analysis (MP4 4664 kb)

Step-by-step description of percutaneous ASD closure, as imaged at TEE. After ASD sizing, the left disk and the central waist of the device are sequentially opened in the left atrium and carefully approached to the atrial septum. As soon as the central waist fills the atrial septal defect, the right disk of the device is deployed in order to stabilize the device. Then, a “push and pull” maneuver is performed to test the device stability. Finally, the device is released and any residual shunt is imaged by color Doppler analysis (MP4 6051 kb)

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer International Publishing AG, part of Springer Nature

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Santoro, G. et al. (2019). ASD Closure in Special Situations: Elderly, PA-IVS. In: Butera, G., Chessa, M., Eicken, A., Thomson, J.D. (eds) Atlas of Cardiac Catheterization for Congenital Heart Disease. Springer, Cham. https://doi.org/10.1007/978-3-319-72443-0_24

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-72443-0_24

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-72442-3

  • Online ISBN: 978-3-319-72443-0

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics