Abstract
Multigap Resistive Plate Chambers (MRPCs) are gaseous detectors that are known to have good time resolution. We have taken an attempt to develop a six gap bakelite MRPC using bakelite plates procured from local market with each gas-gap thickness of 250 \(\upmu \)m. The developed MRPC was tested for its different parameters like efficiency, noise rate with cosmic rays. In this document, the method of fabrication and test results of the MRPC will be presented.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
E. Cerron Zeballos et al., Nucl. Instrum. Meth. A 373, 132–135 (1996)
S. An et al., Nucl. Instrum. Meth. A 594, 39–43 (2008)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG, part of Springer Nature
About this paper
Cite this paper
Ganai, R., Mondal, M., Mehta, S., Ahammed, Z., Chattopadhyay, S. (2018). Development of 6-Gap Bakelite Multi-gap Resistive Plate Chamber (MRPC). In: Naimuddin, M. (eds) XXII DAE High Energy Physics Symposium . Springer Proceedings in Physics, vol 203. Springer, Cham. https://doi.org/10.1007/978-3-319-73171-1_28