Skip to main content

Monte Carlo dosimetry with PENELOPE code of the VariSource VS2000 192Ir high dose rate brachytherapy source

  • Conference paper
World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany

Part of the book series: IFMBE Proceedings ((IFMBE,volume 25/1))

  • 103 Accesses

Abstract

Recommendations of the American Association of Physicists in Medicine TG-43U1 report have been followed to characterize the Varisource VS2000 192Ir high dose rate brachytherapy source, provided by Varian Oncology Systems. Monte Carlo calculations with PENELOPE code have been carried out in order to obtain dosimetric parameters for this source: air kerma strength, dose rate constant, radial dose function and anisotropy function. These quantities are compared to the source reference data, finding results in agreement with them taking respective uncertainties into account. Outcomes stated in this paper provide a complete parameter collection, which can be used for dosimetric calculations as well as a means of comparison with other datasets from this source

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Casado, F.J., Mateo, B., Cenizo, E., García-Pareja, S., Galán, P., Bodineau, C. (2009). Monte Carlo dosimetry with PENELOPE code of the VariSource VS2000 192Ir high dose rate brachytherapy source. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/1. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03474-9_43

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03474-9_43

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03472-5

  • Online ISBN: 978-3-642-03474-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics