Skip to main content

Classification of Wrist Pulse Blood Flow Signal Using Time Warp Edit Distance

  • Conference paper
Medical Biometrics (ICMB 2010)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 6165))

Included in the following conference series:

Abstract

The blood flow signals can be used to examine a person’s health status and have been widely used in the study of the clinical diagnosis of cardiovascular diseases. According to the pulse diagnosis theory of traditional chinese, the pathological changes of certain organs could be reflected on the wrist pulse signals. In this paper, we use Doppler ultrasonic device to collect the wrist pulse blood flow signals from patients with pancreatitis (P), duodenal bulb ulcer (DBU), appendicitis (A) and acute appendicitis (AA) as well as healthy persons. After extracting the envelopes of ultrasonic pulse contour, the wrist pulse blood flow signals are pre-processed using wavelet transform. Finally, we adopted a recent time series matching method, time warp edit distance (TWED), on the pre-processed data for classification of wrist pulse blood flow signals. The proposed approach is tested on the wrist blood flow signal dataset, and achieves higher classification accuracy than several classical time series matching approaches, such as Euclidean distance (ED), dynamic time warping (DTW), and edit distance with real penalty (ERP).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Lukman, S., He, Y., Hui, S.: Computational methods for traditional Chinese medicine: a survey. Computer Methods and Programs in Biomedicine 88, 283–294 (2007)

    Article  Google Scholar 

  2. Zhu, L., Yan, J., Tang, Q., Li, Q.: Recent progress in computerization of TCM. Journal of Communication and Computer 3, 78–81 (2006)

    Google Scholar 

  3. Wang, K., Xu, L., Zhang, D., Shi, C.: TCPD based pulse monitoring and analyzing. In: Proceedings of the 1st ICMLC conference, Beijing (2002)

    Google Scholar 

  4. Wang, H., Cheng, Y.: A quantitative system for pulse diagnosis in Traditional Chinese Medicine. In: Proceedings of the 27th IEEE EMB conference, Shanghai (2005)

    Google Scholar 

  5. Chen, Y., Zhang, L., Zhang, D., Zhang, D.: Wrist Pulse Signal Diagnosis using Modified Gaussian Models and Fuzzy C-Means Classification. Medical Engineering & Physics 31, 1283–1289 (2009)

    Article  Google Scholar 

  6. Chen, Y., Zhang, L., Zhang, D., Zhang, D.: Computerized Wrist Pulse Signal Diagnosis using Modified Auto-regressive Models. Journal of Medical Systems (September 2009)

    Google Scholar 

  7. Lu, W., Wang, Y., Wang, W.: Pulse analysis of patients with severe liver problems. IEEE Eng. in Med. and Biol. 18, 73–75 (1999)

    Article  Google Scholar 

  8. Zhang, A., Yang, F.: Study on recognition of sub-health from pulse signal. In: Proceeding of ICNNB Conference, vol. 3, pp. 1516–1518 (2005)

    Google Scholar 

  9. Zhang, D., Zhang, L., Zhang, D., Zheng, Y.: Wavelet-based analysis of Doppler ultrasonic wrist-pulse signals. In: Proceeding of ICBBE Conference, Shanghai, vol. 2, pp. 589–543 (2008)

    Google Scholar 

  10. Zhang, D., Zuo, W., Zhang, D., Zhang, H., Li, N.: Wrist Blood Flow Signal-based Computerized Pulse Diagnosis Using Spatial and Spectrum Features. J. Biomedical Science and Engineering, 6 pages (2010)

    Google Scholar 

  11. Marteau, P.-F.: Time Warp Edit Distance with Stiffness Adjustment for Time Series Matching. IEEE Trans. Pattern Analysis and Machine Intelligence 31, 306–318 (2009)

    Article  Google Scholar 

  12. Chen, Y., Zhang, L., Zhang, D., Zhang, D.Y.: The public Pulse Signal Dataset (2010), http://www4.comp.polyu.edu.hk/~cslzhang/Pulse_datasets.htm

  13. Xu, L., Zhang, D., Wang, K.: Wavelet-based cascaded adaptive filter for removing baseline drift in pulse waveforms. IEEE Trans. Biomed. Eng. 52, 1973–1975 (2005)

    Article  Google Scholar 

  14. Wagner, R.A., Fischer, M.J.: The String-to-String Correction Problem. J. ACM 21, 168–173 (1973)

    Article  MathSciNet  Google Scholar 

  15. Mäkinen, V.: Using Edit Distance in Point-Pattern Matching. In: Proc. Eighth Symp. String Processing and Information Retrieval (SPIRE 2001), pp. 153–161 (2001)

    Google Scholar 

  16. Chen, L., Ng, R.: On the Marriage of LP-Norm and Edit Distance. In: Proc. Int’l. Conf. Very Large Data Bases, pp. 792–801 (2004)

    Google Scholar 

  17. Keogh, E., Ratanamahatana, C.A.: Exact indexing of dynamic time warping. Knowledge and Information Systems 7, 358–386 (2005)

    Article  Google Scholar 

  18. Sakoe, H., Chiba, S.: Dynamic programming algorithm optimization for spoken word recognition. IEEE Trans. Acoustics, Speech, and Signal Proc. 26, 43–49 (1978)

    Article  MATH  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Liu, L., Zuo, W., Zhang, D., Li, N., Zhang, H. (2010). Classification of Wrist Pulse Blood Flow Signal Using Time Warp Edit Distance. In: Zhang, D., Sonka, M. (eds) Medical Biometrics. ICMB 2010. Lecture Notes in Computer Science, vol 6165. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13923-9_14

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-13923-9_14

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-13922-2

  • Online ISBN: 978-3-642-13923-9

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics