Diaphragm Tracking in Cardiac C-Arm Projection Data

  • Chapter
  • First Online:
Bildverarbeitung für die Medizin 2012

Part of the book series: Informatik aktuell ((INFORMAT))

Abstract

Long acquisition times of several seconds lead to image artifacts in cardiac C-arm CT. These artifacts are mostly caused by respiratory motion. In order to improve image quality, it is important to accurately estimate the breathing motion that occurred during image acquisition. It has been shown that diaphragm motion is correlated to the respiration-induced motion of the heart. We describe the development of a method that is able to accurately track the contour of the diaphragm in projection space using a 2D quadratic curve model of the diaphragm to simplify the process. In order to provide robust and stable tracking, additional constraints based on prior knowledge of the projection geometry and human anatomy are introduced. Results show that the tracking is very accurate. A mean model error per pixel of 0.93 ± 0.44 pixels for the left and 0.79 ± 0.19 pixels for the right hemidiaphragm was observed. The diaphragm top is tracked with an even lower error of only 0.75 ± 0.84 pixels for the left and 0.45 ± 056 pixels for the right hemidiaphragm respectively.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 99.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 129.00
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Jahnke C, Paetsch I, Achenbach S, et al. Coronary MR imaging: breath-hold capability and patterns, coronary artery rest periods, and beta-blocker use. Radiology. 2006;239:71–8.

    Article  Google Scholar 

  2. Wiesner S, Yaniv Z. Respiratory signal generation for retrospective gating of cone- beam CT images. Proc SPIE. 2008;6918:71.

    Google Scholar 

  3. Marchant TE, Price GJ, Matuszewiski BJ, et al. Reduction of motion artefacts in on-board cone beam CT by warping of projection images. Br J Radiol. 2011;84:251– 64.

    Article  Google Scholar 

  4. Wang Y, Riederer S, Ehman R. Respiratory motion of the heart: kinematics and the implications for spatial resolution in coronary imaging. Magn Reson Med. 1995;33:716–19.

    Google Scholar 

  5. Sonke JJ, Zijp L, Remeijer P, et al. Respiratory correlated cone beam CT. Med Phys. 2005;32:1176–86.

    Article  Google Scholar 

  6. Canny FJ. A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell. 1986;8(6):679–98.

    Article  Google Scholar 

  7. Fischler MA, Bolles RC. Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography. Commun ACM. 1981;24:381–95.

    Article  MathSciNet  Google Scholar 

  8. Segars WP, Mahesh M, Beck TJ, et al. Realistic CT simulation using the 4D XCAT phantom. Med Phys. 2008;35(8):3800–8.

    Article  Google Scholar 

  9. Schwemmer C, Prummer M, Daum V, et al. High-Density object removal from projection images using low-frequency-based object masking. Proc BVM. 2010; p. 365–9.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Marco Bögel .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2012 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Bögel, M., Maier, A., Hofmann, H.G., Hornegger, J., Fahrig, R. (2012). Diaphragm Tracking in Cardiac C-Arm Projection Data. In: Tolxdorff, T., Deserno, T., Handels, H., Meinzer, HP. (eds) Bildverarbeitung für die Medizin 2012. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-28502-8_8

Download citation

Publish with us

Policies and ethics