The evidence and the clinical applicability of angioeinedensitometry is very much determined by the reproducibility of the densitometric values measured. These values should be objective and comparable to each other. This is more important for the velocity profile and phase-dependent instantaneous flow volumina in pulsatile blood flow than for mean blood flow velocities and volumina. In any case the evaluation is based on the density curves measured from the X-ray film. Figure 1 shows such density curves, recorded at nearly the same region of the femoral artery in several patients. The curves clearly differ very much. They do contain information about distinct blood flow characterics, but mainly they contain false information. The falsifications are caused by the varying conditions of injection of contrast medium.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Decker D, Faust U, Heuck F (1980) Hydraulischer Hochdruck-Injektor mit digitalem Injektionsprozessor. Biomed Tech 25:58–62

    Article  CAS  Google Scholar 

  • Epple E, Decker D, Heuck F (1974) Meß-und Auswerteverfahren der Röntgen-Cine-Densitometrie mit einer Datenverarbeitungsanlage. Fortschr Röntgenstr 120(3):345–353

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1983 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Decker, D., Faust, U., Reiser, U. (1983). Model Experiments for Angiocinedensitometry. In: Heuck, F.H.W. (eds) Radiological Functional Analysis of the Vascular System. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-68957-4_7

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-68957-4_7

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-68959-8

  • Online ISBN: 978-3-642-68957-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics