Skip to main content

Physical Properties of the Thermal Environment

  • Conference paper
Thermoregulation of Sick and Low Birth Weight Neonates
  • 120 Accesses

Abstract

For more than 100 years specific equipment has been used to keep newborns warm [1]. The first air-controlled incubator with integrated humidification was designed in 1947 [1] by Chappie. Since then, and especially in the last 15 years, birth weights have decreased to as low as 450g and gestational ages to as early as the 24th week of gestation. These very small newborns have different heat losses than full term babies: the heat loss by evaporation is much higher [2], the ratio of surface area to body weight is less favourable and body heat production is very limited. This results in greater requirements from warming therapy equipment and these are described in this paper.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Marx FF (1968) Die Entwicklung der Säuglingsinkubatoren. Verlag Siering KG, Bonn

    Google Scholar 

  2. Hammarlund, Sedin, Strömberg Transepidermal Waterloss in Newborn Infants. Acta Paediatrica Scandinavia, Vol. 72, pp 721–728, 1983

    Article  CAS  Google Scholar 

  3. Brück K Fetal and neonatal physiology, volume 1, chapter 48: Neonatal thermal regulation, figure 48–2, page 490

    Google Scholar 

  4. Wasner J. (1995) Heat balance calculation for newborns in incubators. Dräger Medizintechnik aktuell, 1.95, brochure Dräger

    Google Scholar 

  5. IEC 601–2–35 Particular requirements for the safety of heated mattresses

    Google Scholar 

  6. IEC 601–2–19 Particular requirements for the safety of incubators

    Google Scholar 

  7. Evaluation (1984) Infant radiant warmers, Health Devices, Vol 13 No.7

    Google Scholar 

  8. IEC 601–2–21 Particular requirements for the safety of radiant warmers

    Google Scholar 

  9. Harpin VA, Rutter N (1985) Humidification of incubators. Arch Dis Child 60:219

    Article  PubMed  CAS  Google Scholar 

  10. Ducker (1994) Hygiene report with humidification in incubators, submitted to: Archive of Childhood, and brochure Dräger

    Google Scholar 

  11. Hey EN, Katz G. (1969) Evaporative water loss in newborn baby. Journal of Physiology, 200

    Google Scholar 

  12. Brück (1994) Messungen der Körpertemperaturen von sehr kleinen Frühgeborenen während der ersten Lebenswoche. Dissertation, Universität Düsseldorf

    Google Scholar 

  13. Frankenberger H (1991) Inkubatoren. Verlag TÃœV Rheinland

    Google Scholar 

  14. Sjörs G a.o. (1992) An Evaluation of Environment and Climate Control in Seven Infant Incubators. Biomedical Instrumentation & Technology, and: Boone, Otho a.o.: Thermal Evaluation of Four Commercially Available Double Wall Incubators, presented at the 86th Annual Scientific Assembly of the Southern Medical Association

    Google Scholar 

  15. Agate FJ, Silverman WA: (1963) The control of body temperature in the small newborn infant by low-energy infra-red radiation. Pediatrics 31:725.

    PubMed  Google Scholar 

  16. Sjörs G, Hammarlund K, Kjartensson S and Sedin G (1994) Thermal balance in term infants nursed in an incubator with a radiative heat source. Pediatric Research 35, (2) 278 abs 115

    Article  Google Scholar 

  17. Tunell R (1987) The evaluation of different methods to provide warmth to newborn babies by the use of baby thermal manikin. Zukünftige Entwicklung medizinischer Technik in der Pädiatrie, edited by P. Lemburg and J. Koch, Drägerwerk AG Lübeck

    Google Scholar 

  18. Knauth A, Gordin M, NcNelis W, Baumgart S; (1989) Semipermeaable Polyurethane membrane as an artificial skin for the premature neonate. Pediatrics 83:945

    PubMed  CAS  Google Scholar 

  19. Sarman I, Tunell R (1989) Providing warmth for preterm babies by a heated, water filled mattress. Archives of Disease in Childhood 64: 29–33 and:

    Article  PubMed  CAS  Google Scholar 

  20. Sarman I, Can G, Tunell R (1989) Rewarming preterm infants on a heated, water filled mattress. Archives of Disease in Childhood 64: 687–692

    Article  PubMed  CAS  Google Scholar 

  21. Rutter (1992) Temperature control and its disorders. Textbook of neonatology, second edition, Chuchill Livingstone

    Google Scholar 

  22. Marshall HK, Avroy AF Care of the high-risk neonate. Chapter 5: The physical environment. Page 114–129, W.B. Saunders Company

    Google Scholar 

  23. Baumgart S (1986) Partitioning of heat losses and gains in premature newborn infants under radiant warmers. Pediatrics 75: 89

    Google Scholar 

  24. Malin S, Baumgart S (1987) Optimal thermal management for low birth weight infants nursed under high powered radiant warmers. Pediatrics 79; 47

    PubMed  CAS  Google Scholar 

  25. Standard for safety of humidifiers: ISO 7185

    Google Scholar 

  26. Ducker DA, Lyon AJ, Ross RR, Bass CA, Mcintosh N (1985) Incubator temperature control: effects on the very low birthweight infant. Archives of Disease in Childhood 60: 902 – 907

    Article  PubMed  CAS  Google Scholar 

  27. Okken A, Blijam C, Franz W, Bohn E (1982), Effects of forced convection of heated air on insensible water loss and heat loss in preterm infants in incubators. Journal of Pediatrics 101: 108–112

    Article  PubMed  CAS  Google Scholar 

  28. Frankenberger H (1991) Inkubatoren. Verlag TÃœV Rheinland, Seite 64ff

    Google Scholar 

  29. Bell EF, et al (1980) Heat balance in premature infants; comparative effects of convectively heated incubator and radiant warmer, with and without plastic heat shield. J. Pediatr 96:460

    Article  PubMed  CAS  Google Scholar 

  30. Calder KH, Nardis EE and Ultmann JS (1984) A warming mattress for premature infants. Pediat.Res. 18, 333 A, Abstract 1427

    Google Scholar 

  31. Baumgart S, et al (1981) Effect of heat shielding on convective and evaporative heat losses and on radiant heat transfer in premature infant. J Pediatr 99:948

    Article  PubMed  CAS  Google Scholar 

  32. Bell EF (1983) Infant incubators and radiant warmers. Early Human Development, 8, 351–375

    Article  PubMed  CAS  Google Scholar 

  33. Gagge AP Standard operative temperature, a generalised temperature scale, applicable to direct and partitional calorimetry, American Journal of Physiology, 31, 1940, p. 93–103

    Google Scholar 

  34. Topper WH, Stewart TP Thermal support for the very-low-birth-weight infant: Role of supplemental conductive heat: The Journal of Pediatrics, Vol. 105, Number 5, p. 810–814

    Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1995 Springer-Verlag Berlin

About this paper

Cite this paper

Koch, J. (1995). Physical Properties of the Thermal Environment. In: Okken, A., Koch, J. (eds) Thermoregulation of Sick and Low Birth Weight Neonates. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-79934-1_10

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-79934-1_10

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-79936-5

  • Online ISBN: 978-3-642-79934-1

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics