Summary

The three years of operational experience with the measurement equipment of the SSPS-CRS has demonstrated that three main areas need improvement:

  1. 1.

    The measurement sensors should be calibrated periodically to guarantee the availability and accuracy of the measurements.

  2. 2.

    Additional measurement equipment should be installed to separate the measurement sensors from the control sensors and to allow measurement of the beam quality of all the heliostats, optical power into the cavity, spillage losses, and the stair-step of the circumsolar factor by hand.

  3. 3.

    The control and measuring systems should be separated completely, and control and data evaluation programs installed in their own computers. The data acquisition system should have its own front-end computer to receive the data evaluation of the measurements.

The appendix of the report contains the results of two calibration campaigns on the thermocouples and flowmeters. The examination of 12 relevant thermocouples resulted in deviations somewhat above the guaranteed tolerance of the NiCr-Ni sensors used. But with the help of the described polynominal and special coefficients for every thermocouple, these deviations can be corrected. The examination of the most important flowmeter, LK01CF01 of the sodium circuit, resulted in deviations in the range of 2.79% up to 11.29% less displayed. The deviation depends on the absolute value of the flow in m3/hr.

The deviations stated are much higher than the expected inaccuracy of ± 2.5% over the whole measuring range. This flowmeter has been exchanged for a new, exact calibrated one.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1986 Springer-Verlag GmbH Berlin Heidelberg

About this chapter

Cite this chapter

Brinner, A. (1986). Improvements in Measuring Equipment. In: Kesselring, P., Selvage, C.S. (eds) The IEA/SSPS Solar Thermal Power Plants — Facts and Figures— Final Report of the International Test and Evaluation Team (ITET). Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-82684-9_30

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-82684-9_30

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-16149-3

  • Online ISBN: 978-3-642-82684-9

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics