Water temperature is surveyed and simulated in a small mountainous reservoir (Matalavilla, NW Spain) in order to assess the thermal and hydrodynamic effects of a projected pumped-storage hydroelectric plant in the water body and downstream on the Sil River. Detailed field measurements were taken from June 2014 to November 2015 including meteorology, radiation balance over the water surface, water temperature of tributaries and thermal vertical profiles inside the reservoir. Such database provides information to analyse the current thermal and hydrodynamic behaviour of the system as well as to calibrate and validate the two-dimensional water quality model CE-QUAL-W2 for the simulation of the future pumped-storage plant scenario. The model satisfactorily reproduces the intensity and temporal occurrence of the thermal processes observed in the reservoir, with a mean error below 0.05 °C (root mean square error below 1.1 °C) at a daily temporal scale and 1 m vertical spatial scale. Currently, in the absence of the projected pumped-storage plant, Matalavilla Reservoir is subjected to an important flow regulation for hydroelectric generation purposes, which influences its thermal structure. When the water column is stratified (summer, according to its annual monomictic thermal cycle), it presents two well-defined thermoclines: one generated from the atmosphere–water interface, whose location is related to the water surface position and whose stability is highly sensitive to the inflows regime; and another one related to the level of the reservoir water outlet, located in depth next to the dam and fairly stable most of the year. In the presence of the projected pumped-storage hydroelectric plant, the model results predict the homogenisation and heating of intermediate depths of the water column and mixing about one month earlier. Water outflow from the reservoir to the downstream Sil River would be slightly warmer, up to a maximum temperature increase of 1.5 °C under the ordinary interbasin transfer management.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 389.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 499.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 499.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Deane, J. P., Gallachóir, B. P. Ó., & McKeogh, E. J. (2010). Techno-economic review of existing and new pumped hydro energy storage plant. Renewable and Sustainable Energy Reviews, 14(4), 1293–1302.

    Article  Google Scholar 

  2. Gimeno-Gutiérrez, M., & Lacal-Arántegui, R. (2013). Assessment of the European potential for pumped hydropower energy storage, technical report. Netherlands: Joint Research Centre of the European Commission.

    Google Scholar 

  3. González, J. S., Vega, J. M. R., Villar, A. G., & Gutiérrez, R. B. G. (2010). Los aludes de nieve en el Alto Sil (Oeste de la Cordillera Cantábrica, España). Cuadernos de Investigación Geográfica, 36(1), 7–26.

    Google Scholar 

  4. Cole, T. M., & Wells, S. A. (2015). CE-QUAL-W2: A two-dimensional, laterally averaged, hydrodynamic and water quality model, version 3.72. Portland, OR: Department of Civil and Environmental Engineering, Portland State University.

    Google Scholar 

  5. Hanna, R. B., Saito, L., Bartholow, J. M., & Sandelin, J. (1999). Results of simulated temperature control device operations on in-reservoir and discharge water temperatures using CE-QUAL-W2. Lake and Reservoir Management, 15(2), 87–102.

    Article  Google Scholar 

  6. Boegman, L., Loewen, M. R., Hamblin, P. F., & Culver, D. A. (2001). Application of a two-dimensional hydrodynamic reservoir model to Lake Erie. Canadian Journal of Fisheries and Aquatic Sciences, 58(5), 858–869.

    Article  Google Scholar 

  7. Bowen, J. D., & Hieronymus, J. W. (2003). A CE-QUAL-W2 model of Neuse Estuary for total maximum daily load development. Journal of Water Resources Planning and Management, 129(4), 283–294.

    Article  Google Scholar 

  8. Modiri-Gharehveran, M., Etemad-Shahidi, A., & Jabbari, E. (2013). Effects of climate change on the thermal regime of a reservoir. Proceedings of the ICE-Water Management, 167(10), 601–611.

    Google Scholar 

  9. Vega, J. C. (2013). Informe sobre la calidad ambiental del agua de los embalses de Rozas, Matalavilla, Peñarrubia, Campañana, Prada, San Sebastián y Pias, Informe realizado para ENDESA GENERACIÓN, S. A. Puebla de Sanabria, Zamora (Spain).

    Google Scholar 

  10. Armengol, J., Caputo, L., Comerma, M., Feijoó, C., García, J. C., Marcé, R., et al. (2003). Sau reservoir’s light climate: Relationships between Secchi depth and light extinction coefficient. Limnetica, 22(1–2), 195–210.

    Google Scholar 

Download references

Acknowledgements

This work has been funded by ENDESA, S. A. within the project ‘Hydrodinamic study of Matalavilla Reservoir’. The authors wish to thank D. Niñerola, J. Pomares, X. Martínez and M. Griñón of Flumen Institute for their assistance with instrumentation and fieldwork, as well as R. Poncelas and the NW Hydraulic Production Unit personnel of ENDESA for their collaboration.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Anaïs Ramos-Fuertes .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Ramos-Fuertes, A., Palau, A., Dolz, J. (2018). Application of a Two-Dimensional Water Quality Model (CE-QUAL-W2) to the Thermal Impact Assessment of a Pumped-Storage Hydropower Plant Project in a Mountainous Reservoir (Matalavilla, Sil River, Spain). In: Gourbesville, P., Cunge, J., Caignaert, G. (eds) Advances in Hydroinformatics . Springer Water. Springer, Singapore. https://doi.org/10.1007/978-981-10-7218-5_20

Download citation

Publish with us

Policies and ethics