Abstract
Oxygen saturation is an important parameter for people with breathing and heart problems to monitor their oxygen levels. The method proposed here uses pulse oximeter sensor to measure SpO2 (oxygen saturation). In this, two LEDs (Red and IR) with different wavelengths are used to obtain the signal from finger. Noninvasive system permits pain-free continuous monitoring of patient with minimum risk of infection. The oxygen saturation (SpO2) in blood is obtained and it is transmitted wirelessly through Bluetooth and further, these data can be given to the doctor through cloud. Noninvasively obtained SpO2 is compared with the standard device values. This measurement can provide early warning to potential problems that your body may potentially be facing.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
http://janeshealthykitchen.com/24-ways-increase-blood-oxygenation/
Mohan, P.M., Nisha, A.A., Nagarajan, V., Jothi, E.S.J.: Measurement of arterial oxygen saturation (SpO2) using PPG optical sensor. In: International Conference on Communication and Signal Processing (ICCSP), pp. 1136–1140. IEEE (2016)
Jarosz, A., Kolacinski, C., Wasowski, J., Szymanski, A., Kurjata-Pfitzner, E., Obrebski, D., Pleskacz, W.A.: Design and measurements of the specialized VLSI circuit for blood oxygen saturation monitoring. In: 14th International Conference the Experience of Designing and Application of CAD Systems in Microelectronics (CADSM), pp. 448–451. IEEE (2017)
Gao, F., Peng, Q., Feng, X., Gao, B., Zheng, Y.: Single-wavelength blood oxygen saturation sensing with combined optical absorption and scattering. IEEE Sens. J. 16(7), 1943–1948 (2016)
Peng, Q., Gao, F., Feng, X., Zheng, Y.: Continuous Blood Oxygen Saturation Detection with Single-Wavelength Photoacoustics (2015)
Shao, D., Liu, C., Tsow, F., Yang, Y., Du, Z., Iriya, R., Tao, N.: Noncontact monitoring of blood oxygen saturation using camera and dual-wavelength imaging system. IEEE Trans. Biomed. Eng. 63(6) (2016)
Feng, L., Po, L.M., Xu, X.L.Y., Ma, R.: Motion-resistant remote imaging photo plethysmography based on the optical properties of skin. IEEE Trans. Circuits Syst. Video Technol. 25(5), 879–891 (2015)
Maziar, T., Turicchia, L., Sarpeshkar, R.: An ultra-low-power pulse oximeter implemented with an energy-efficient Trans impedance amplifier. IEEE Trans. Biomed. Circuits Syst. 4(1), 27–38 (2010)
Ogunduyile, O.O., Oludayo, O.O., Lall, M.: Development of wearable systems for ubiquitous healthcare service provisioning. APCBEE Procedia 7, 163–168 (2013)
Fu, Yu., Jian, Liu: System design for wearable blood oxygen saturation and pulse measurement device. Procedia Manuf. 3, 1187–1194 (2015)
Mishra, D., Priyadarshini, N., Chakraborty, S., Sarkar, M.: Blood oxygen saturation measurement using polarization-dependent optical sectioning. IEEE Sens. J. 17(12), 3900–3908 (2017)
Zijlstra WG, A Buursma., WP Meeuwsen-Van der Roest (1991) Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin. Clinical chemistry 37.9: 1633–1638
Reddy, K.A., George, B., Mohan, N.M., Kumar, V.J.: A novel method for the measurement of oxygen saturation in arterial blood. In: Instrumentation and Measurement Technology Conference (I2MTC), pp. 1–5. IEEE (2011)
Martinez, L.: A non-invasive spectral reflectance method for mapping blood oxygen saturation in wounds. In: Proceedings of 31st Applied Imagery Pattern Recognition Workshop. IEEE (2002)
Kraitl, J., Klinger, D., Fricke, D., Timm, U., Ewald, H.: Non-invasive measurement of blood components. In: Advancement in Sensing Technology, pp. 237–262. Springer, Berlin, Heidelberg (2013)
MAXREFDES117:http://datasheet.octopart.com/MAXREFDES117%23-Maxim-Integrated-datasheet-66615138.pdf
Acknowledgements
The authors are grateful to Karunya Institute of Technology and Sciences for providing needful facilities to do the experiment.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Ashisha, G.R., Anitha Mary, X., Rajasekaran, K., Jegan, R. (2019). IoT-Based Continuous Bedside Monitoring Systems. In: Peter, J., Alavi, A., Javadi, B. (eds) Advances in Big Data and Cloud Computing. Advances in Intelligent Systems and Computing, vol 750. Springer, Singapore. https://doi.org/10.1007/978-981-13-1882-5_34
Download citation
DOI: https://doi.org/10.1007/978-981-13-1882-5_34
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-1881-8
Online ISBN: 978-981-13-1882-5
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)