Skip to main content

Immunobiosensors based on grating couplers

  • Protocol
Affinity Biosensors

Part of the book series: Methods in Biotechnology ((MIBT,volume 7))

Abstract

Immunosensors based on grating couplers belong to the group of direct optical affinity sensors (1). They allow label-free monitoring not only of lmmunoaffinity reactions, i.e., of antigen (hapten)-antibody-binding (28), but also of receptor—ligand-(9), protein—lipid (10, 11), and protein—DNA (12, 13) interactions, and DNA hybridization (13). In each case one of the binding partners is immobilized on the surface of the optical waveguide and binding of the other partner, present in solution, is monitored. Thus, grating coupler systems allow real-time monitoring of the binding reaction and consequently evaluation of kinetic (1416) and thermodynamic data (4, 12). These are common features with other direct affinity sensor systems, such as surface plasmon resonance sensors (15), resonant mirrors (17), and piezoacoustic transducers (18), which all can be summarized as devices for biomolecular interaction analysis.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Protocol
USD 49.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.00
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Tiefenthaler, K. (1992) Integrated optical couplers as chemical waveguide sensors. Adv Biosens 2, 261–289.

    Google Scholar 

  2. Lukosz, W., Clerc, D., Nellen, P M., Stamm, C, and Weiss, P. (1991) Output grating couplers on planar optical waveguides as direct immunosensors. Biosens Bioelectron 6, 227–232.

    Article  PubMed  CAS  Google Scholar 

  3. Nellen, P M. and Lukosz, W. (1991) Model experiments with integrated optical input grating couplers as direct immunosensors. Biosens Bioelectron 6, 517–525

    Article  PubMed  CAS  Google Scholar 

  4. Polzius, R., Bier, F F., Bilitewski, U., Jager, V., and Schmid, R. D. (1993) On-line monitoring of monoclonal antibodies in animal cell culture using a grating coupler. Biotechnol Bioeng. 42, 1287–1292.

    Article  PubMed  CAS  Google Scholar 

  5. Clerc, D. and Lukosz, W. (1994) Integrated optical output grating coupler as biochemical sensor. Sensors Actuators B18–19, 581–586.

    Google Scholar 

  6. Bier, F. F. and Schmid, R. D. (1994) Real time analysis of competitive binding using grating coupler immunosensors for pesticide detection. Biosens. Bioelectron. 9, 125–130.

    Article  CAS  Google Scholar 

  7. Bernard, A. and Bosshard, H. R. (1995) Real-time monitoring of antigen-antibody recognition on a metal oxide surface by an optical grating coupler sensor. Eur. J. Biochem. 230, 416–423.

    Article  PubMed  CAS  Google Scholar 

  8. Gao, H., Sanger, M., Luginbühl, R., and Sigrist, H. (1995) Immunosensing with photo-immobilized immunoreagents on planar optical wave guides. Biosens, Bioelectron. 10, 317–328.

    Article  CAS  Google Scholar 

  9. Jockers, R., Bier, F. F., and Schmid, R. D. (1993) Specific binding of photosynthetic reaction centres to herbicide-modified grating couplers. Anal. Chim. Acta 280, 53–59

    Article  CAS  Google Scholar 

  10. Ramsden, J. J., Bachmanova, G. L, and Archakov, A. I. (1996) Immobilization of proteins to lipid bilayers. Biosens. Bioelectron 11, 523–528

    Article  PubMed  CAS  Google Scholar 

  11. Heyse, S., Vogel, H., Sanger M., and Sigrist, H. (1995) Covalent attachment of functionalized lipid bilayers to planar waveguides for measuring protein binding to biomimetic membranes. Prot. Sci. 4, 2532–2544.

    Article  CAS  Google Scholar 

  12. Ramsden, J. J. and Dreier, J. (1996) Kinetics of the interaction between DNA and the type IC restriction enzyme Eco R124II. Biochemistry 35, 3746–3753.

    Article  PubMed  CAS  Google Scholar 

  13. Bier, F. F. and Scheller, F. W. (1996) Label-free observation of DNA-hybndisation and endonuclease activity on a waveguide surface using a grating coupler. Biosens. Bioelectron. 11, 669–674.

    Article  PubMed  CAS  Google Scholar 

  14. Ramsden, J. J. (1993) Experimental methods for investigating protein adsorption kinetics at surfaces, Q Rev Biophys 27, 41–105.

    Article  Google Scholar 

  15. Lukosz, W. (1991) Principles and sensitivities of integrated optical and surface plasmon sensors for direct affinity sensing and immunosensing Biosens Bioelectron. 6, 215–225

    Article  Google Scholar 

  16. Polzius, R., Schneider, T., Bier, F. F., Bilitewski, U., and Koschinski, W (1996) Optimization of biosensing using grating couplers: immobilization on tantalum oxide waveguides. Biosens. Bioelectron 11, 503–514.

    Article  PubMed  CAS  Google Scholar 

  17. Cush, R, Cronin, J. M., Stewart, J., Maule, C. H., Molloy, J., and Goddard, N. J. (1993) The resonant mirror a novel optical biosensor for direct sensing of biomolecular interactions part I: principles of operation and associated instrumentation. Biosens. Bioelectron. 8, 347–353.

    Article  CAS  Google Scholar 

  18. Ngeh-Ngwainbi, J., Suleiman, A., and Guilbault, G. G. (1990) Piezoelectric crystal biosensors. Biosens. Bioelectron. 5, 13–26

    Article  PubMed  CAS  Google Scholar 

  19. Tiefenthaler, K. and Lukosz, W. (1989) Sensitivity of grating couplers as integrated-optical chemical sensors, J. Opt. Soc. Am. B6, 209–220.

    Google Scholar 

  20. Tiefenthaler, K., Briguet, V., Buser, E., Horisberger, M., and Lukosz, W. (1983) Preparation of planar SiO2-TiO2 and LiNbO3 waveguides with dip coating method and an embossing technique for fabrication of grating couplers and channel waveguides. SPIE 401, 165–173.

    CAS  Google Scholar 

  21. Kunz, R. E., Du, C. L., Edlinger, J., Pulker, H K., and Seifert, M (1991) Integrated optical sensors based on reactive low-voltage ion-plated films. Sensors Actuators A 25–27, 155–159.

    Google Scholar 

  22. Lukosz, W and Tiefenthaler, K. (1983) Directional switching in planar waveguides effected by adsorption-desorption processes. 2nd ECIO, Florence, IEE Conf Pub. No 227, London, 152.

    Google Scholar 

  23. Nellen, P. M., Tiefenthaler, K., and Lukosz, W. (1990) Integrated optical input grating couplers as chemo-and immunosensors. Sensors Actuators Bl, 592–596

    Google Scholar 

  24. Lukosz, W., Nellen, P., Stamm, C, and Weiss, P (1990) Output grating couplers on planar waveguides as integrated optical chemical sensors. Sensors Actuators Bl, 585–588.

    Google Scholar 

  25. Brandenburg, A., Polzius, R., Bier, F., Bilitewski, U., and Wagner, E. (1996) Direct observation of affinity reactions by reflected mode operation of integrated optical grating coupler. Sensors Actuators B30, 55–59.

    CAS  Google Scholar 

  26. Lukosz, W. and Tiefenthaler, K. (1988) Sensitivity of integrated optical grating and prism couplers as (bio)chemical sensors. Sensors Actuators 15, 273–284.

    Article  CAS  Google Scholar 

  27. Lofas, S and Johnsson, B. (1990) A novel hydrogel matrix on gold surfaces in surface plasmon resonance sensors for fast and efficient covalent immobilization ofhgands. J Chem Soc. Chem. Commun 21, 1526–1528.

    Article  Google Scholar 

  28. Glaser, R. W. (1993) Antigen-antibody binding and mass transport by convection and diffusion to a surface: a two-dimensional computer model of binding and dissociation kinetics Anal Biochem. 213, 152–161.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1998 Humana Press Inc., Totowa, NJ

About this protocol

Cite this protocol

Bilitewski, U., Bier, F., Brandenburg, A. (1998). Immunobiosensors based on grating couplers. In: Rogers, K.R., Mulchandani, A. (eds) Affinity Biosensors. Methods in Biotechnology, vol 7. Humana Press. https://doi.org/10.1385/0-89603-539-5:121

Download citation

  • DOI: https://doi.org/10.1385/0-89603-539-5:121

  • Publisher Name: Humana Press

  • Print ISBN: 978-0-89603-539-3

  • Online ISBN: 978-1-59259-485-6

  • eBook Packages: Springer Protocols

Publish with us

Policies and ethics