Abstract

Lengthening and then plating (LATP) was used to decrease the total time needed in external fixation in this patient with complex bilateral mutiaplical oblique plane deformities. A 16 year old girl with rickets was treated with multilevel osteotomies of both femurs and tibias, and deformity correction and lengthening was performed with monolateral external fixators. Plating was performed, and frames were removed before complete bone union. This allowed early removal of frames and protection against refracture.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 449.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 649.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References and Suggested Reading

  • Anglen J, Kyle RF, March JL, Virkus WW, Watters WC III, Keith MW et al (2009) Locking plates for extremity fractures. J Am Acad Orthop Surg 17:466–472

    Google Scholar 

  • Aronson J (1997) Limb lengthening, skeletal reconstruction and bone transport with the Ilizarov method. J Bone Joint Surg 79A:1243–1258

    Google Scholar 

  • Bar-On E, Weigl DM, Becker T et al (2008) Treatment of severe early onset Blount’s disease by an intra-articular and a metaphyseal osteotomy using the Taylor Spatial Frame. J Child Orthop 2:457–461

    Article  PubMed Central  PubMed  Google Scholar 

  • Clark SE, McCarthy JJ, Davidson RS (2009) Treatment of Blount disease: a comparison between the multiaxial correction system and other external fixators. J Pediatr Orthop 29:103–109

    Article  Google Scholar 

  • Dodgin DA, De Swart RJ, Stefko RM et al (1998) Distal tibial/fibular derotation osteotomy for correction of tibial torsion: review of technique and results in 63 cases. J Pediatr Orthop 18:95–101

    CAS  PubMed  Google Scholar 

  • Edgerton BC, Mariani EM, Morrey BF (1993) Distal femoral varus osteotomy for painful genu valgum: a five-to-11-year follow-up study. Clin Orthop Relat Res 288:263–269

    PubMed  Google Scholar 

  • Feldman DS, Madan SS, Ruchelsman DE et al (2006) Accuracy of correction of tibia vara: acute versus gradual correction. J Pediatr Orthop 26:794–798

    Article  PubMed  Google Scholar 

  • Friend L, Widemann RF (2008) Advances in management of limb length discrepancy and lower limb deformity. Curr Opin Pediatr 20:46–51

    Article  PubMed  Google Scholar 

  • Gugenheim JJ Jr, Brinker MR (2003) Bone realignment with use of temporary external fixation for distal femoral valgus and varus deformities. J Bone Joint Surg Am 85:1229–1237

    PubMed  Google Scholar 

  • Gugenheim JJ, Brinker MR, Oginni LM, Bardu OS, Sharp CA, Davie MWJ, Worsfold M (2004) Knee angles and rickets in Nigerian children. J Pediatr Orthop 24:403–407

    Article  Google Scholar 

  • Harbechuski R, Fragomen AT, Rozbruch SR (2012) Does lengthening and then plating (LAP) shorten duration of external fixation? Clin Orthop Rel Res 470:1771–1781 (Epub ahead of print November 15, 2011)

    Article  Google Scholar 

  • Herring JA (1983) Valgus knee deformity: etiology and treatment. J Pediatr Orthop 3:527

    Article  CAS  PubMed  Google Scholar 

  • Knapp DR, Price CT (1990) Correction of the distal femoral deformity. Clin Orthop Relat Res 255:75–80

    PubMed  Google Scholar 

  • Krengel WF III, Staheli LT (1992) Tibial rotational osteotomy for idiopathic torsion. A comparison of the proximal and distal osteotomy levels. Clin Orthop Relat Res 283:285–289

    PubMed  Google Scholar 

  • Kubiak EN, Fulkerson E, Strauss E, Egol KA (2006) The evolution of locked plates. J Bone Joint Surg Am 88(Suppl 4):189–200

    Article  PubMed  Google Scholar 

  • McCarthy JJ, Ranade A, Davidson RS (2008) Pediatric deformity correction using a multiaxial correction fixator. Clin Orthop Relat Res 466:3011–3017

    Article  PubMed Central  PubMed  Google Scholar 

  • Paley D (2003) Principles of deformity correction. Springer, New York

    Google Scholar 

  • Seah KM, Shafi R, Fragomen AT, Rozbruch SR (2011) Distal femoral osteotomy: is internal fixation better than external? Clin Orthop Relat Res 469:2003–2011

    Article  PubMed Central  PubMed  Google Scholar 

  • Vander Have KV, Herrera J, Kohen R, Karunakar M (2008) The use of locked plating in skeletally immature patients. J Am Acad Orthop Surg 16:436–441

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to León Gonzalo Mora Herrera .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this entry

Cite this entry

Mora Herrera, L.G. (2015). Case 33: Multiapical Deformity Correction in Bilateral Femur and Tibia in Rickets. LATP Technique to Decrease the Time of External Fixator. In: Rozbruch, S., Hamdy, R. (eds) Limb Lengthening and Reconstruction Surgery Case Atlas. Springer, Cham. https://doi.org/10.1007/978-3-319-18020-5_210

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-18020-5_210

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-18019-9

  • Online ISBN: 978-3-319-18020-5

  • eBook Packages: MedicineReference Module Medicine

Publish with us

Policies and ethics