Abstract
Periarticular deformity of the distal femur has been treated successfully with external fixation. Often a ring fixator is required to keep the osteotomy distal enough for accurate realignment. Although with the use of a fixator, one is able to achieve correction of the deformity and length, it comes with great discomfort, scarring, and impingement to knee motion. The LAP (lengthening and then plating) technique was designed to reduce the time in the frame by early conversion to a plate. This technique was complicated by difficulty controlling the distal femoral fragment, infection, and plate failure. With the introduction of a reliable internal lengthening nail, the problem of periarticular deformity and leg length discrepancy (LLD) can be reassessed. In the following case, a distal femoral plate is used to achieve an acute correction of a procurvatum deformity, and an internal lengthening nail is used proximally for limb length equalization providing an all-internal alternative to a complex problem.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References and Suggested Reading
Baumgart R (2009) The reverse planning method for lengthening of the lower limb using a straight intramedullary nail with or without deformity correction. A new method. Oper Orthop Traumatol 21(2):221–233
Harbacheuski R, Fragomen AT, Rozbruch SR (2012) Does lengthening and then plating (LAP) shorten duration of external fixation? Clin Orthop Relat Res 470(6):1771–1781
Kirane YM, Fragomen AT, Rozbruch SR (2014) Precision of the PRECICE internal bone lengthening nail. Clin Orthop Relat Res 472(12):3869–3878
Paley D, Herzenberg JE, Paremain G, Bhave A (1997) Femoral lengthening over an intramedullary nail. A matched-case comparison with Ilizarov femoral lengthening. J Bone Joint Surg Am 79(10):1464–1480
Schiedel FM, Vogt B, Tretow HL, Schuhknecht B, Gosheger G, Horter MJ, Rödl R (2014) How precise is the PRECICE compared to the ISKD in intramedullary limb lengthening? Acta Orthop 85(3):293–298
Seah KT, Shafi R, Fragomen AT, Rozbruch SR (2011) Distal femoral osteotomy: is internal fixation better than external? Clin Orthop Relat Res 469(7):2003–2011
Thaller PH, Fürmetz J, Wolf F, Eilers T, Mutschler W (2014) Limb lengthening with fully implantable magnetically actuated mechanical nails (PHENIX(®))-preliminary results. Injury 45(Suppl 1):S60–S65
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer International Publishing Switzerland
About this entry
Cite this entry
Fragomen, A.T. (2015). Case 15: Periarticular Femur Deformity and LLD: A Modern Approach. In: Rozbruch, S., Hamdy, R. (eds) Limb Lengthening and Reconstruction Surgery Case Atlas. Springer, Cham. https://doi.org/10.1007/978-3-319-18020-5_309
Download citation
DOI: https://doi.org/10.1007/978-3-319-18020-5_309
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-18019-9
Online ISBN: 978-3-319-18020-5
eBook Packages: MedicineReference Module Medicine