Abstract

In active thermography, heat is directed into a test object in order to detect inhomogeneities and cavities. When a test object is heated or cooled, temperature differences at the surface are caused due to local variations in the thermal conductivities and heat capacities of the test specimen. These are recorded and evaluated using a thermography system. The most important methods used in this process are pulse thermography, pulsed phase thermography, and lock-in thermography.

This paper first describes the basic measurement set-ups and the functional principles. Then possibilities of how to heat the test specimens are explained. External energy sources, such as radiation, convection, and heat conduction, heat the surface. With internal energy sources such as ultrasonic excitation, microwaves and inductive stimulation, in contrast, the heating takes place in the volume of the test specimen. If the specimen is excited with a short pulse, then this is referred to as pulse thermography. A special evaluation of the pulse response is pulsed phase thermography. If the excitation ensues in a sinusoidal form, then this is known as lock-in thermography.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

References

  • Breitenstein O, Warta W, Langenkamp M (2010) Lock-in thermography. Springer, Berlin

    Book  Google Scholar 

  • Maierhofer C, Myrach P, Krankenhagen R, Röllig M, Steinfurth H (2015) Detection and Characterization of Defects in Isotropic and Anisotropic Structures Using Lockin Thermography Journal of Imaging. https://doi.org/10.3390/jimaging1010220

  • Maldague XPV, Moore PO (eds) (2001) Nondestructive testing handbook. American Society for Nondestructive Testing, Columbus

    Google Scholar 

  • Zhang H, Yang R, He Y, Foudazi A, Cheng L, Tian G (2017) A review of microwave thermography nondestructive testing and evaluation. Sensors 17(5):1123. https://doi.org/10.3390/s17051123

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Gerald Gerlach .

Editor information

Editors and Affiliations

Section Editor information

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer International Publishing AG, part of Springer Nature

About this entry

Check for updates. Verify currency and authenticity via CrossMark

Cite this entry

Budzier, H., Gerlach, G. (2018). Active Thermography. In: Ida, N., Meyendorf, N. (eds) Handbook of Advanced Non-Destructive Evaluation. Springer, Cham. https://doi.org/10.1007/978-3-319-30050-4_13-1

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-30050-4_13-1

  • Received:

  • Accepted:

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-30050-4

  • Online ISBN: 978-3-319-30050-4

  • eBook Packages: Springer Reference EngineeringReference Module Computer Science and Engineering

Publish with us

Policies and ethics